Grindmaster PBIC-430V2E230 User Manual

Page of 44
Shuttle Brewers & Airpot/Shuttle Brewers
Page 7
Adjustments
All adjustments to machine are accessible through the front display(s). Refer to specifics below and the
Programming Routine section. All values are preset at the factory and may vary brewer to brewer.
Temperature Adjustment
Tank temperature can be adjusted from 170°F – 205°F (77°C – 96°C) through the front display. See Programming
Routine section for procedure.
Altitude (ft)
Approximate Boiling Point
Recommended Max. Temperature
°F
°C
°F
°C
0
212
100
205
96.1
500
211.1
99.5
204
95.6
1000
210.2
99.0
203
95.0
1500
209.3
98.5
202
94.4
2000
208.4
98.0
201
93.9
2500
207.5
97.5
200
93.3
3000
206.6
97.0
199
92.8
3500
205.7
96.5
199
92.8
4000
204.8
96.0
198
92.2
4500
203.9
95.5
197
91.7
5000
203
95.0
196
91.1
5500
202
94.4
195
90.6
6000
201.1
93.9
194
90.0
6500
200.2
93.4
193
89.4
7000
199.3
92.9
192
88.9
7500
198.3
92.4
191
88.3
This brewer can be set for maximum water temperature of 205°F (96°C). The boiling point of water is lower as 
altitude increases. The setpoint temperature of the brewer should be maintained below the boiling point at a given
elevation. Refer the to the chart below for recommended maximum setpoint for given altitudes.
THERMISTOR CURVE FOR PART # A725-097
°C
°F
RESISTANCE (OHMS)
°C
°F
RESISTANCE (OHMS)
0
32
16325
60
140
1244
5
41
12697
65
149
1041
10
50
9951
70
158
875
15
59
7856
75
167
740
20
68
6246
80
176
628
25
77
5000
85
185
535
30
86
4028
90
194
458
35
95
3266
95
203
393
40
104
2663
100
212
339
45
113
2185
105
221
294
50
122
1802
110
230
255
55
131
1493