Bunn CDS-3 User Manual

Page of 60
29
SERVICE (cont.)
COMPRESSOR & COMPONENTS (CDS-2) (cont.)
Compressor Start Capacitor:
1.  Check  for  continuity  across  the  terminals  on  the 
compressor start capacitor.
If continuity is present as described, the start capacitor 
is operating properly.
If  continuity  is  not  present  as  described,  replace  the 
capacitor.
NOTE:  If  all  the  electrical  components  are  operating 
properly and the compressor does not operate, there is an 
internal mechanical problem. Replace the compressor.
Removal and Replacement:
Compressor Assy:
NOTE: Before removal of any refrigeration component 
the  refrigerant  in  the  system  must  be  reclaimed  by  a 
licensed refrigeration repair person.
1.  Disconnect the tubes from the condenser and the 
accumulator.
2.  Disconnect the compressor wiring harness from the 
dispenser main wiring harness.
3.  Remove the four .25-20 keps nuts and washers se-
curing the compressor to the chassis. Set nuts and 
washers aside for reassembly.
4.  Remove the four #8-32 locking screws securing the 
component bracket to the dispenser chassis.
5.  Disconnect the wires from the circuit breaker, fuse 
holder, transformer, electronic control and the con-
tactor.
6.  Remove component bracket with circuit breaker, fuse 
holder, transformer, electronic control and contactor 
as an assembly. Set component bracket and screws 
aside for reassembly.
7.  From the right side of the dispenser lift the compres-
sor assembly over the four studs in the chassis and 
remove compressor.
8.  Install new compressor over the four studs in the 
dispenser chassis with the fill valve to the left side 
of the dispenser.
9.  Secure compressor to the dispenser chassis using 
four .25-20 keps nuts and washers.
10. Reconnect the wires to the components on the com-
ponent bracket and plug the main wiring harness into 
the electronic control.
NOTE:  When  reconnecting  wires  refer  to  Fig.  10  for 
circuit breaker, Fig. 34 for fuse holder, Fig. 51 for trans-
former and Fig. 22 for contactor.
11. Position the component bracket in the chassis and 
secure with four #8-32 locking screws.
12. Reconnect tubes from the condenser and the ac-
cumulator to the compressor.
13. Evacuate the system.
NOTE:  When  replacing  the  compressor  it  is  recom-
mended that the dryer also be replaced.
14. Recharge 120V system with 8.4 oz. of Type R22 
refrigerant. Design Pressures: High 210 - Low 32
 
Recharge 230V system with 9.5 oz. of Type 404A 
refrigerant. Design Pressures: High 215 - Low 40
NOTE: The charging of the system must be done by a 
licensed refrigeration repair person.
Compressor Start Capacitor: Refer to FIG. 12 
WARNING:  The  compressor  start  capacitor  must  be 
properly discharged before proceeding.
1.  Remove  terminal  cover  retainer  (6)  and  terminal 
cover (5). Set aside for reassembly.
2.  Disconnect the two leads from the capacitor.
3.  Pry the end of the capacitor mounting bracket off of 
the boss on the capacitor and remove the capaci-
tor.
4.  Install  new  capacitor  on  the  capacitor  mounting 
bracket.
5.  Refer to Fig. 13 and reconnect the wires to the ca-
pacitor.
6.  Reinstall terminal cover (5) and cover retainer (6).
FIG. 13 COMPRESSOR START CAPACITOR 
TERMINALS
P1340
120V DISPENSERS
230V DISPENSERS
27646 122200