SERVICE (cont.)
COMPRESSOR & COMPONENTS (CDS-3)
FIG. 16 COMPRESSOR &
COMPONENT LOCATIONS
FIG. 17 COMPRESSOR THERMAL
OVERLOAD PROTECTOR LOCATION
3.  Disconnect the black wire to the thermal overload 
protector (4), the white and black or red wires to 
the compressor.
4.  With a voltmeter, check voltage across the black wire 
removed from the thermal overload protector and 
the white wire with the ON/OFF switch in the “ON” 
position, DAY/NIGHT switch in the “DAY” position 
and the ICE/OFF/NO ICE switch in the “ICE” posi-
tion. Connect the dispenser to the power source. 
The indication must be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt models.
5.  Disconnect the dispenser from the power source.
If  voltage  is  present  as  described,  proceed  to  #6. 
If voltage is not present as described, refer to the Wiring 
Diagram and check the dispenser wiring harness.
6.  Disconnect the two black wires from the compres-
sor start capacitor.
7.   Check for continuity across contacts 1 & 2 of the 
relay.
If continuity is present as described, the compressor 
start relay is operating properly.
If continuity is not present as described, replace re-
lay.
Compressor:
1.   With the compressor start relay (1) removed, discon-
nect the black or red wire from the compressor.
2.  Check  for  continuity  across  the  terminal  on  the 
compressor and the left pin on the compressor.
If continuity is present as described, the electrical part 
of the compressor is operating properly.
If continuity is not present as described, replace the 
compressor.
Thermal Overload Protector:
1.  Check for continuity across the terminals on the 
thermal overload protector.
If continuity is present as described, the thermal over-
load protector is operating properly.
If continuity is not present as described, replace the 
thermal overload protector.
Compressor Start Capacitor:
1.  Check for continuity across the terminals on the 
compressor start capacitor.
If continuity is present as described, the start capacitor 
is operating properly.
If continuity is not present as described, replace the 
capacitor.
Location:
The compressor assy is located inside the front 
of the dispenser chassis.
 
1. Compressor Start Relay
 
2. Compressor Start Capacitor
 
3. Compressor Run Capacitor
 
4. Thermal Overload Protector
 
5. Overload Protector Retainer
 
6. Compressor Terminal Cover
 
7. Compressor Terminal Cover Retainer
Test Procedures: 
Compressor Start Relay: Refer to FIG. 17
WARNING: The compressor capacitors must be prop-
erly discharged before proceeding.
1.  Disconnect the dispenser from the power source.
2.  Remove  the  compressor  terminal  cover  retainer 
(7) and compressor terminal cover (6).
P1558.30