SERVICE (cont.)
CONTACTOR - ELECTRONIC CONTROL
6.  Disconnect the black wires from contactor termi-
nals #6 & #8 (#5 & #6, CDS-3 first type contac-
tor).
7.  With ON/OFF switch in the “ON” position, connect 
the dispenser to the power source and check for 
continuity across terminals on contactor.
If continuity is not present as described, on CDS-3 first 
type contactors, replace contactor. If continuity is not 
present between terminals #6 & #8 as described on all 
CDS-2 contactors and CDS-3 second type contactors, 
check for continuity across terminals #2 and #4.
If continuity is present as described, disconnect the 
dispenser  from  power  source  and  reconnect  black 
wires to terminals #2 and #4, the contactor will oper-
ate properly.
If continuity is not present as described, replace the 
contactor.
Removal and Replacement:
1.  Disconnect the wires from the contactor.
2.  Remove the two #8-32 locking screws securing 
the contactor to the component bracket. Remove 
and discard contactor.
3.  Install the new contactor on the component bracket 
using two #8-32 locking screws.
4.  Refer to Fig. 22 and reconnect the wires.
FIG. 22 CONTACTOR TERMINALS
P1333
R2
2
FIG. 21 CONTACTOR - ELECTRONIC CONTROL
Location:
The contactor is located inside the dispenser chas-
sis on the lower outside of the component bracket.
Test Procedures:
1.  Disconnect  the  dispenser  from  the  power 
source.
2.  Disconnect white/black wire from contactor termi-
nal #0 (terminal #2, on CDS-3 first type contactor) 
and brown/black from terminal #1.
3.  With  a  voltmeter,  check  the  voltage  across  the 
white/black  wire  and  the  brown/black  wire  and 
the ON/OFF switch in the “ON” position. Connect 
the dispenser to the power source. The indication 
must be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt models.
4.  Disconnect  the  dispenser  from  the  power 
source.
If voltage is present as described, proceed to #5.
If  voltage  is  not  present  as  described,  refer  to  the 
Wiring Diagram and check the dispenser wiring har-
ness.
5.  Check for continuity across contactor terminals 
#0 & #1 (#1 & #2, CDS-3 first type contactor).
If  continuity  is  present  as  described  reconnect  the 
white/black  wire  and  the  brown/black  wire  to  the 
contactor and proceed to #6.
If continuity is not present as described, replace the 
contactor.
P1342
ALL CDS-2 CONTACTORS
CDS-3 SECOND TYPE CONTACTORS
CDS-3 FIRST TYPE CONTACTORS
27646 122200
Terminal #0
WHI/BLK from Main Harness/
Power Cord/Compressor
Terminal #1
BRN/BLK  from  Main
Harness/Control Board
Terminal #6
BLK from Main
Harness/Power Cord
Terminal #8
BLK from Compressor
Harness
Terminal #2
Terminal #4
Terminal #1
BRN/BLK  from  Main
Harness/Control Board
Terminal #6
BLK from Main
Harness/Power Cord
Terminal #2
WHI/BLK from Main Harness/
Power Cord/Compressor
Terminal #5
BLK from Compressor
Harness