Bunn CDS-3 User Manual

Page of 60
36
SERVICE (cont.)
DAY/NIGHT SWITCH
If  continuity  is  present  as  described,  the  day/night 
switch is operating properly.
If continuity is not present as described, replace the 
day/night switch.
Removal and Replacement:
1.  Pull the dispenser drawer out until the drawer hits 
the drawer stop. Using a screwdriver gently pry up 
on the drawer stop and remove the drawer from 
the dispenser.
2.  Remove the four #8-32 locking screws securing 
the switch panel to the drawer.
3.  Lift switch panel with wires and L.E.D. board as an 
assembly.
4.  Turn switch panel over and remove the wires from 
the DAY/NIGHT switch.
5.  Compress the clips on the back of the control panel 
and gently push switch through the opening.
6.  Push the new switch into the opening, with the “o” 
on the switch to the outside, until the clips snap 
into position.
7.  Reconnect the wires to the switch. Refer to Fig. 26 
when reconnecting wires.
8.  Position  the  switch  panel  inside  the  drawer  and 
secure with four #8-32 locking screws.
9.  Reinstall drawer.
FIG. 26 DAY/NIGHT SWITCH TERMINALS
P1335
FIG. 25 DAY/NIGHT SWITCH
P1343
Location:
The DAY/NIGHT switch is located inside the dis-
penser drawer on the right front of the control panel.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the white/green wire from the switch 
and the white/black wire from contactor located on 
the outside bottom of the component bracket .
3.  With  a  voltmeter,  check  the  voltage  across  the 
white/green and the white/black  and the ”ON/OFF“ 
switch in the “ON” position. Connect the dispenser 
to the power source. The indication must be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, reconnect the white/
black wire to the contactor and proceed to #5.
If voltage is not present as described, refer to the Wiring 
Diagram and check the dispenser wiring harness.
5.  Remove the white/red wire from the transformer.
6.  With the DAY/NIGHT switch in the “DAY” position 
check for continuity across the terminals. Continu-
ity must not be present when the switch is in the 
“NIGHT” position.
27646 122200