Smeg ALFA135V6 User Manual

Page of 17
 
Instructions for the Installer
 
 
 
 
25 
 
 
 
 
The power supply lead supplied is of 
H07RN-F type, gauge 3 x 4 mm
2
.  
For operation at 
380-415V2N
  or  380-
415V3N
, the power supply cable has to be 
replaced with one of H07RN-F type. The 
gauge of the wires in the new cable must be 
at least 2.5-1.5 mm
2
 (4 x 2.5 mm
- 5  x 
1.5 mm
2
), bearing in mind that the earth wire 
(yellow-green) must be at least 20 mm 
longer at the end for connection to the oven.
 
 
 
  
In case of connection to the electrical mains by means of socket and pin, 
the connection must be completed with a three-pin plug of suitable rating 
(25A), or, for operation at 380-415V2N
  /  380-415V3N
, a five-pin plug 
(16A). The power supply plug and wall socket must be of the same type 
(in compliance with CEI standards). Check that the power supply line is 
properly earthed. The use of reductions, adapters or junctions is not 
recommended. 
 
  
If a permanent connection to the electrical mains is used, the appliance's 
power supply line must be fitted with an omnipolar breaking device with 
contact breaking gap of at least 3 mm, located in an easily accessible 
position close to the appliance itself. 
 
 
 
 
WARNING: if the mains voltage drops below 190 VAC there might be 
an impairment of the oven's performance; this is not due to the 
appliance itself.