Smeg A21X-6 User Manual

Page of 32
 
Instructions for the installer 
 
6
 
2.  INSTALLATION OF THE APPLIANCE 
 
 
It is the law that all gas appliances are installed by 
authorised persons
Clearance around the cooker must comply with the requirements of  
AS5601.
 
2.1 Electrical connection 
 
Make sure that the power line voltage matches the specifications 
indicated on the rating plate located inside the storage compartment.  
This rating plate must never be removed. 
 
 
The plug at the end of the power cable and the wall socket must be the 
same type (conforming to regulations in force). Check that the power line 
is adequately grounded. Do not use reducers, adapters or shunts. 
 
 
On the power line, install an omnipolar cut-off device with contact cut-off 
distance greater than or equal to 3 mm, located in an easily accessible 
position near the unit. 
 
 
 
 
Use an H05RR-F-type three-core cable (3 x 
2.5 mm
2
). 
 
The cable end to be connected to the 
appliance must be provided with an ground 
wire (yellow-green) at least 20 mm longer.
 
 
 
 
The manufacturer declines all responsibility for damage to persons 
or things caused by non-observance of the above prescriptions or by 
interference with any part of the appliance. 
 
 
Overall dimensions: location of gas and electrical connection points (all 
measures in mm). 
 
 
 
 
 
110  
760  
150  
170