Instructions for the installer 
 
 
2.2 Gas connection 
 
This appliance is suitable for installation with Natural 
Gas or ULPG (propane). Refer to page 12 for the 
relevant burner pressure and appropriate injector sizes. 
When the appliance is to be connected to Natural Gas 
then the pressure regulator supplied must be fitted to the 
gas inlet. A test point (for checking the gas pressure) is 
supplied either with the regulator or as a separate fitting 
in the case of ULPG (propane) appliances. 
Connection of the appliance to the gas supply must be in 
accordance with the requirements of AS5601. A ½” BSP 
connector at the inlet is recommended and the gas 
supply line to the appliance must be of adequate length 
to allow sufficient withdrawal of appliance for service or 
disconnection and be: 
1.
 
annealed copper pipe or; 
2.
 
flexible hose according to AS/NZ1869 & be at 
least Class “B”, 10 mm diameter. 
The appliance must be installed with provision to allow the gas to be 
turned off and disconnected for servicing and removal of the appliance 
as required from the gas supply. 
Before the appliance is operated make certain all relevant parts are 
placed in the correct position. 
When the installation is completed the installation connections of 
appliance will require to be leak tested, the burner operating pressure 
and flame checked and adjusted. 
Warranty service calls do not cover these adjustments! 
To check the operating pressure of the appliance it is recommended at 
least 2 large size burners are used. Ensure appliance is secured to wall 
when installation is completed. 
N.G. The regulator supplied must be fitted to the ½ BSP thread at the 
rear of the appliance. An approved manual shut-off valve must be 
installed. The N.G. regulator must be checked and adjusted to 1.0kPa 
after installation.
 
ULPG: Can be connected to the inlet fitting directly. The 
pressure must be checked to ensure it is operating at 
2.75kPa. A separate test point fitting must be installed 
between the piping & the appliance for the pressure to 
be checked to ensure it is operating at 2.75kPa.