Instructions for the installer 
 
 
REQUIREMENTS 
1
 
Overhead clearances – (Measurement A
Range hoods
 and exhaust fans shall be installed in accordance with 
the manufacturer’s instructions. However, in no case shall the 
clearance between the highest part of the 
hob 
of the cooking 
appliance
 and a 
range hood
 be less than 600 mm or, for an overhead 
exhaust fan, 750 mm
Any other downward facing 
combustible surface
 less than 600 mm 
above the highest part of the 
hob
 shall be protected for the full width 
and depth of the cooking surface area in accordance with Clause 
5.12.1.2. However, in no case shall this clearance to any surface be 
less than 450 mm
2
 
Side clearances – (Measurements B & C
Where  B, measured from the periphery of the nearest 
burner
 to any 
vertical 
combustible surface
, is less than 200 mm, the surface shall 
be protected in accordance with Clause 5.12.1.2 to a height C of not 
less than 150 mm above the 
hob
 for the full dimension (width or 
depth) of the cooking surface area. Where the cooking 
appliance
 is 
fitted with a ‘splashback’, protection of the rear wall is not required. 
3
 
Additional requirements for Freestanding and Elevated Cooking 
Appliaces – (Measurements D & E
Where  D, the distance from the periphery of the nearest 
burner
 to a 
horizontal 
combustible surface
 is less than 200 mm, then E shall be 
10 mm or more, or the horizontal surface shall be above the 
trivet
See insets above. 
 
NOTES 
1
 
Requirement 3 does not apply to a freestanding or elevated 
cooking appliance which is designed to prevent flames or the 
cooking vessels from extending beyond the periphery of the 
appliance. 
2
 
The ‘cooking surface area’ is defined as that part of the 
appliance where cooking normally takes place and does not 
include those parts of the appliance containing control knobs. 
3
 
For definition of hob, see Clause 1.4.64. 
4
 
For definition of trivet, see Clause 1.4.109. 
5
 
Consideration is to be given to window treatments when 
located near cooking appliances. See Clause 5.3.4.