Cornelius 3 User Manual

Page of 74
Viper Service Manual                                 
Publication Number: 621360041TBSER
- 50 -
© 2010, IMI Cornelius Inc.
COMPONENT REPLACEMENT
The following are procedures for servicing the major components of the Viper 
system.
B
ARREL
 M
OTOR
 S
EAL
 R
EPLACEMENT
The barrel motor seal is typically replaced during the semi-annual preventative 
maintenance procedure. The seal location is shown in Figure 40.
Figure 40. Front View Inside of Barrel w/ Faceplate off
Removing the Existing Seal
To remove the existing barrel seal, perform the procedure in Table 42.
Motor
Seal
Motor
Shaft
Table 42
Step
Action
1.
2
When purging is complete, disconnect power from the unit.
3
Open the relief valve on the front of the barrel to ensure that pressure is 
released. 
CAUTION: Barrel pressure MUST be relieved before removing the 
faceplate!
4
Remove the four (4) 3/4 in. nuts from the faceplate and slowly remove the 
faceplate from the unit.
5
Carefully pull the blade assembly out of the barrel.
6
Remove any remaining product from the barrel.
7
Rinse and inspect the blade assembly and barrel for signs of wear. (Replace if 
necessary)
8
Remove the seal and spacer from the rear of barrel.
9
When old seal and spacer are removed, use a clean soft cloth to clean 
between the motor shaft and the barrel to remove any remaining product.