For non-vented (recirculating) installations:
The charcoal filter is not washable. It should last up to 6 months 
with normal use.
1. Replace metal grease filter with a charcoal filter. For 
information on ordering, see the “Accessories” section.
To replace filter:
1. Remove screw from the grease filter retainer.
2. Turn the grease filter retainer to release filter. 
3. Reinstall the filter by placing the back edge in the channel at 
rear of hood. Push filter into place, turn the filter retainer to 
secure filter to range hood.
4. Replace screw in the grease filter retainer.
Replacing the Incandescent Light Bulb
Turn off the range hood and allow the light bulb to cool.
1. Disconnect power.
2. Squeeze the plastic lens cover and remove it from the hood. 
3. Screw light bulb into socket. 
4. Replace lens cover by squeezing cover and inserting tabs 
into slots.
5. Reconnect power.
If new light does not operate, make sure the lamp is inserted 
correctly before calling service.
WIRING DIAGRAM
A. Light bulb socket
B. Lens cover
A
B
L
3
2
1
C25
SE114A
1.2 ±10% A
73 ±10% Watts
17.1 ±10% Ohms
13.6 ±10% Ohms
Motor Characteristics
Power Supply
120 VAC
Frequency
60 Hz
Amperage
Wattage Rating
Motor Resistance
White - Red
White - Black
    Lamp Switch 
 Off - Low - High
   Motor Switch 
      Off - On
Lamp Switch 
  Operation
1 - 3
Low
1 - 2
Off
1 - L High
Ground
 Screw
GND
L
N
BK
WH
RD
Speed 2
Common
Speed 1
RD
WH
NOTE: Speed 1
   not used
RD
BK
BK
RD
BK
WH
BK
WH
YL
Rectifier
  Diode