Smeg GCS70XG User Manual

Page of 17
 
Instructions for the installer 
 
30 
 
 
5.2 
Regulation for LPG 
 
   
 
  Loosen screw A  and push support B  all the way. Use a double head 
wrench to remove nozzle C  and assemble the suitable one, following 
the instructions indicated in the reference charts, with respect to the 
type of gas to use. The screwing torque of the nozzle should never 
exceed  3 Nm. Reposition support B  so that nozzle C  is covered 
perfectly. 
Move the Venturi tube D  to regulate the air flow until distance “X” is 
reached indicated in the chart in paragraph “5.4 Regulation of primary 
air” and then secure the tube by means of screw A. After the regulations 
have been carried out, restore the seals with sealing wax or equivalent 
material.
 
 
   
 
 
 
Burner 
Rated 
heating 
capacity 
LPG – G30/G31 28/37 mbar 
 
 
Nozzle 
diameter 
1/100 mm
By-pass 
1/100 mm 
Reduced 
flowrate 
(W) 
Flowrate 
g/h G30 
Flowrate 
g/h G31 
Auxiliary 
1.05 
48 
30 (1) 
380 
76 
75 
Semirapid 
1.65 
62 
30 (1) 
380 
120 
118 
Rapid 
2.55 
76 
37 (2) 
650 
185 
182 
Rapid large 
3.1 
85 
43 
750 
225 
222 
Fish pan 
67 
43 (3) 
750 
145 
143 
Ultra rapid 
3.3 
87 
55 (4) 
1200 
240 
236 
Internal 
0.8 
42 
30 (1) 
380 
58 
57 
Double 
crown 
External 
3.3 
87 
55 (4) 
1200 
240 
236 
(1)= 33 for valveless appliances. 
(2)= 40 for valveless appliances. 
(3)= 45 for valveless appliances. 
(4)= 65 for valveless appliances.