Smeg GCS70XG User Manual

Page of 17
Instructions for the installer
 
 
 
31 
 
 
5.3 
Regulation for natural gas 
 
   
 
 The hob has been inspected for G20 (2H) natural gas at a pressure of 
20 mbar. To allow the unit to work with this type of gas, perform the 
same operations described in paragraph “5.2
 
Regulation for LPG”, but 
choose the nozzles and regulate the primary air for natural gas, as 
shown in the following table and in paragraph “5.4
Regulation of primary 
air”. After the regulations have been carried out, restore the seals with 
sealing wax or equivalent material. 
Burner 
Rated 
heating 
capacity 
Natural gas – G20 20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary 
1.05 
73 
380 
Semirapid 
1.65 
92 
380 
Rapid 
2.55 
115 
650 
Rapid large 
3.1 
126 
750 
Fish pan 
2.0 
100 
750 
Ultra rapid 
3.3 
130 
1200 
Internal 
0.8 
67 
380 
Double 
crown 
External 
130 
1200 
3.3 
 
 
5.4 
Regulation of primary air 
 
 Referred to distance “X” in mm. 
Burner 
G20 
20 mbar 
G30/G31 
30/37 mbar 
 
 
 
 
 
 
 
Auxiliary (1) 
1.5 
1.0 
 
 
 
 
 
 
 
Semirapid (2) 
1.5 
1.5 
 
 
 
 
 
 
 
Rapid (3) 
1.0 
1.5 
 
 
 
 
 
 
 
 
Rapid large (4) 
2.5 
10.0 
 
 
Fish pan (7) 
2.0 
2.5 
 
 
Ultra rapid (5) 
2.0 
2.5 
 
 
Ultra rapid (8) 
2.0 
2.5 
 
Internal 
9.0 
1.0 
 
 
 
Double 
crown (6) 
External 
1.5 
8.0 
 
Internal 
1.5 
1.5 
 
 
 
Double 
crown (9) 
External 
1.5 
4.0 
To identify the burners on your hob, refer to the drawings in point  “6.3 Arrangement of burners 
on hob “