Smeg A30E6FXAA User Manual

Page of 12
 
Instructions for the installer
 
 
 
 
 
Do not use reducers, adapters or shunts. 
 
 
 
 
If the power cable is replaced, the wire section on the new cable must 
not be less than 0.75 mm
2
 (3 x 0.75 cable), keeping in mind that the end 
to be connected to the hob must have the ground wire (yellow-green) 
longer by at least 20 mm. Use only H05V2V2-F cable or similar which has 
a maximum temperature of 90°C. Any replacement needed should be 
carried out by a specialised technician who should make the mains 
connections according to the following diagram. 
 
L = brown 
N = blue 
 = yellow-green 
 
 
 
 
 
 
 
The manufacturer will not be liable  for any damage to persons or 
property caused by non-observance of the above instructions or deriving 
from the tampering of even a single part of the hob. 
 
 
 
  2.3  Ventilation of rooms 
 
 
The hob may be installed only in rooms with permanent ventilation, as 
required by standards regulations in force. The room in which the hob is 
installed must have sufficient air flow to satisfy the requirements of 
normal gas combustion and of necessary air exchange in the room. The 
air intakes, protected by screens, must be appropriately sized 
(regulations in force) and placed so as not to be blocked in any way. 
The room where the oven is installed should be suitably ventilated to 
avoid overheating or excess humidity produced by cooking, and in the 
case of lengthy use a window should be opened or the speed of any 
ventilators should be increased. 
 
  2.4  Discharge of combustion products 
 
 
Discharge of combustion products must be guaranteed by means of 
hoods connected to a natural draught flue with certain efficiency, or by 
means of forced aspiration. An efficient aspiration system requires 
careful planning by a specialist capable of installing it, respecting the 
positions and distances prescribed by standards. After installation, the 
installer must issue a certificate of conformity. 
 
19