Smeg GCO90XG User Manual

Page of 20
 
Instructions for the installer
 
 
 
 
31 
5.2 Regulation for LPG 
Loosen screw A and push support B all the way. Use a double head 
wrench to remove nozzle C and assemble the suitable one, following the 
instructions indicated in the reference charts, with respect to the type of 
gas to use. The screwing torque of the nozzle should never exceed         
3 Nm. Reposition support B so that nozzle C is covered perfectly. 
Move the Venturi tube D to regulate the air flow until distance "X" is 
reached indicated in the chart in paragraph "5.4 Regulation of primary air” 
and then secure the tube by means of screw A. After the regulations 
have been carried out, restore the seals with sealing wax or equivalent 
material.
 
 
 
 
 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
LPG – G30/G31  28/37 mbar 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced 
flowrate 
(W) 
Flowrate
g/h G30 
Flowrate 
g/h G31 
Auxiliary (1) 
1.05 
48 
30 
33 (*)
380 
76 
75 
Semi-rapid (2) 
1.65 
62 
30 
33 (*)
380 
120 
118 
Rapid (3) 
3.1 
85 
43 
45 (*)
750 
225 
222 
Ultra rapid (4) 
3.3 
87 
55 
65 (*)
1200 
240 
236 
internal (5) 
1.15 
48 
30 
33 (*)
380 
76 
75 
Double crown 
external (5) 
3.8 
92 
55 
65 (*)
1200 
240 
236 
Fish pan (6) 
2.9 
82 
43 
45 (*)
800 
211 
207 
 
(*) By-pass value for valveless appliances.