Smeg GCO90XG User Manual

Page of 20
 
 
Instructions for the installer
 
 
34 
6.  FINAL OPERATIONS 
Having carried out the above adjustments, reassemble the appliance 
following, backwards, the instructions in paragraph “5.1  Removing the 
hob
”. 
 
 
 
6.1 Regulation of minimum for natural gas 
Replace the components on the burner and slide 
the knobs on the gas tap pins. 
Light the burner and set it at minimum position. 
Remove the knob and turn the regulation screw 
inside or next to the gas tap pin (depending on 
the model) until you get a suitable minimum 
flame. 
Replace the knob and check burner flame 
stability: (rapidly turning the knob from maximum 
to minimum position, the flame should not go 
out). 
 
 
 
6.2 Regulation of minimum for LPG 
To regulate the minimum for LPG, completely tighten (clockwise) the 
screw inside or next to the gas tap pin (depending on the model). 
The diameters of the by-passes for each burner are given in table “5.2 
Regulation for LPG”. 
 
 
 
 
 
After having regulated the device with gas other than the one tested, 
replace the label located on the guard with the one that corresponds to 
the new gas. The label is inside the bag that contains the nozzles 
provided.