Graco 715 User Manual

Page of 14
 4 
DESCRIPTION OF OPERATION 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  The normal “ready” state of the system is as follows: 
  The material supply line is filled with 
dispensable material. 
  The system has been purged, filling the valve 
with material up to the Spool (2).  
  The Spool (2) is seated in the lower Posipak 
Seal (6). 
 
2.  The dispense cycle begins when the controller is 
activated.  Air at 70 psi (4.8 bar) enters the Open 
port and extends the Spool (2) through the lower 
Posipak Seal (6).  
 
3.  Material flows through the Material Inlet (3), around 
the narrow section of the Spool (2) and out through 
the Nozzle (5) (or Needle (12).  Volume can be 
varied by changing the material pressure, nozzle 
size, dispense speed and dispense time. 
 
4.  When the correct amount of material has been 
dispensed, the controller relieves air from the Open 
port and applies air to the Close port.  The Spool (2) 
retracts into the lower Posipak Seal (6) “snuffing” the 
material back into the Nozzle (5), sealing the valve 
and ending the dispensing process. The system is 
again in the normal “ready” state.