4. CONNECTION OF SERVO AMPLIFIER AND SERVO MOTOR 
4 -  2 
 
4.1 Connection instructions 
 
CAUTION
 
To avoid a malfunction, connect the wires to the correct phase terminals (U, V, 
and W) of the servo amplifier (converter unit) and servo motor. 
Do not connect AC power supply directly to the servo motor. Otherwise, it may 
cause a malfunction. 
Do not use the 24 V DC interface power supply for the electromagnetic brake. 
Always use the power supply designed exclusively for the electromagnetic brake. 
Otherwise, it may cause a malfunction. 
 
 
POINT 
 
Refer to chapter 5 for the selection of the encoder cable. 
Refer to the chapter of the servo motor series for the selection of a surge 
absorber for the electromagnetic brake. 
 
For grounding, connect the grounding lead wire from the servo motor to the protective earth (PE) terminal of 
the servo amplifier (converter unit), and then connect the wire from the servo amplifier (converter unit) to the 
ground via the protective earth of the cabinet. Do not connect the wire directly to the protective earth of the 
cabinet. 
Servo motor
Servo amplifier
(converter unit)
Cabinet
PE
terminal
(Note)
(
( )
)
(E)
 
Note. The number of PE terminals of the servo amplifier (converter unit) differs depending 
on the amplifier types.