ACR Electronics RLB-38 User Manual

Page of 31
Y1-03-0250 Rev. B 
18 
4. 
Category II bracket 
Category II brackets are designed to hold the beacon securely in place. The 
beacon  must  be  manually  deployed.  The  bracket  can  be  mounted  on  a 
vertical  flat  surface  with  beacon  antenna  up  or  on  a  horizontal  flat  surface 
facing skyward. This location must be easily accessible in order to manually 
deploy the beacon or to perform the required maintenance and functionality 
tests.  Typical  locations  include  near  the  helm  station  or  just  inside  the 
companionway door. 
 
The  QuickDraw™  Category  II  bracket  has  three  pre-drilled  screw  holes  to 
use for securing the bracket to a flat surface. Remove the beacon from the 
bracket. To  do  this  while  holding  the  assembly,  press  the  “PUSH”  lever  to 
release the beacon from the bracket. Pull the  beacon  forward  and down  to 
remove. The bracket can be held in place to mark the holes. The use of #8 
pan  head  stainless  steel  fasteners  and  washers  (not  included)  is 
recommended.  Be  sure  to  confirm  that  fasteners  will  not  contact  any  wires 
or plumbing before drilling pilot holes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
To  reinstall  the  beacon  inside  the  bracket,  place 
the  antenna  behind  the  top  notch  in  the  bracket. 
The yellow lanyard roll faces the bracket and rests 
in  the  concave  part  of  the  bracket.  Snap  the 
beacon into place by pushing firmly at the bottom 
of  the  beacon  (on  the  ACR  logo)  until  the  snaps 
engage the bottom of the beacon. 
 
 
 
 
 
 
 
Push to Release 
Top in First 
Bottom in Second