ACR Electronics RLB-38 User Manual

Page of 31
Y1-03-0250 Rev. B 
20 
 
STEP FOUR - MAINTAINING THE BEACON 
1. 
Safety DOs and DON’Ts 
 
On a routine basis aboard ship, DO NOT: 
// 
Hold or carry the beacon by its antenna 
// 
Mount the beacon in  its bracket close to large structures or magnetic 
areas  
// 
Tie the lanyard to the EPIRB bracket or any other structure 
// 
Obscure the beacon by placing objects in front of it   
 
On a routine basis aboard ship, DO: 
// 
Mount the beacon in its bracket in an obvious location, so that all can 
see it 
// 
Mount  the  beacon  in  its  bracket with  the  rolled  lanyard  facing  inward 
(facing the bracket)  
// 
Follow the recommended maintenance schedule 
// 
Perform a beacon Self-Test monthly 
// 
Follow up with beacon service if Self-Test fails 
2. 
Routine beacon maintenance 
At  least  every  ninety  days,  the  float  free  mounting  bracket  and  beacon 
should be inspected for deterioration and/or residue buildup that may affect 
the  function  of  the  beacon  or  automatic  release.  Part  of  the  visual  check 
includes  checking  the  antenna  for  tightness.  Clean  the  beacon  and  the 
mounting  bracket  to  remove  any  residue  buildups.  It  is  recommended  that 
the beacon and mounting bracket be wiped with a damp cloth. 
 
Carefully inspect the beacon case for any visible cracks. Cracks may admit 
moisture,  which  could  falsely  activate  the  beacon  or  otherwise  cause  a 
malfunction.  Any  cracks  observed  should  immediately  be  referred  to  ACR 
Service  for  evaluation.  Call  ACR  Electronics  Technical  Service  +1  (954) 
981-3333. 
3. 
Battery replacement 
Battery  replacement  is  due  5  years  from  date  after  the  beacon  placed  into 
service,  or  by  expiry  date  on  the  beacon  whichever  is  first.  During  each 
inspection,  check  the  time  remaining  until  battery
 
replacement  is  required. 
The battery must also be replaced if the beacon has been activated for any 
use other than the Self-Test.