Always refer battery replacement and any other beacon service to a factory 
authorized 
Service 
Center. 
Find 
Center 
near 
you 
at 
Battery 
replacement 
includes 
servicing the beacon by replacing all o-rings, testing the water seal and the 
electrical properties and doing a full functional test on the unit. 
 
NOTE: There are no user serviceable items inside the beacon. Do not open 
the  beacon  except  to  disable  (in  case  of  faulty  or  accidental  activation). 
Otherwise, always have the beacon serviced. 
 
 WARNING: Battery contains lithium 
To  avoid  possible  fire,  explosion,  leakage  or  burn  hazard,  do  not  open, 
recharge,  disassemble  or  heat  beacon  above  +70º  C  (+158º  F)  or 
incinerate. 
 
These products contain lithium in the battery. Various beacons may or may 
not  require  special  shipping  instructions  due  to  the  lithium  batteries  and 
changes  in  shipping  regulations.  Shipping  of  hazardous  materials  requires 
special  handling  and  documentation.  MSDS  sheets,  along  with 
shipping 
information, 
can 
be 
found 
on 
our 
website 
at 
. 
 
In the case of the RLB-38, the product contains small batteries that are non-
hazardous.  However,  regulations  can  change.  Be  advised  that  it  is  best  to 
verify  the  shipping  requirements  at  the  time  you  are  preparing  to  ship  the 
unit.  
4. 
Shore based maintenance for SOLAS vessels, (SBM) IMO 
MSC/Circ. 1039 
The  Maritime  Safety  Committee  has  approved  guidelines  for  shore-based 
maintenance  of  satellite  beacons,  for  the  purpose  of  establishing 
standardized procedures and minimum levels  of service for the testing and 
maintenance of satellite beacons. The first shore based maintenance on all 
ACR EPIRBs is due at the date of the first battery replacement. 
Visit ACR’s 
website  at 
  for  organizations  that  perform  shore 
based maintenance. 
5. 
Annual testing for SOLAS vessels, IMO MSC/Circ. 1040 
SOLAS  regulation  IV/15.9  dictates  annual  testing  of  406  MHz  satellite 
EPIRBs.  Testing  should  be  carried  out  using  suitable  test  equipment 
capable  of  performing  the  relevant  measurements.  All  checks  of  electrical 
parameters  should  be  performed  in  the  self-test  mode,  if  possible.  These 
tests  can  be  performed  by  certified  ACR  Battery  Replacement  Centers 
(BRCs). 
Visit ACR’s website at 
 for authorized ACR 
BRCs.