190
Selection and protection of a motor
453
Second motor capacity
9999
55K or lower
0.4 to 55kW
Set the capacity of the second motor.
75K or higher
0 to 3600kW
9999
V/F control
454
Number of second 
motor poles
9999
2, 4, 6, 8, 10
Set the number of poles of the second motor.
9999
V/F control
455
Second motor 
excitation current
9999
55K or lower
0 to 500A
Tuning data of the second motor
(The value measured by offline auto 
tuning is automatically set.)
75K or higher
0 to 3600A
9999
Use the Mitsubishi motor (SF-JR, SF-HR, 
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series), etc.) constants
456
Rated second motor 
voltage
200/400V 
*
0 to 1000V
Set the rated voltage (V) of the second 
motor.
* The initial value differs according to the 
voltage level. (200V/400V)
457
Rated second motor 
frequency
60Hz
10 to 120Hz
Set the rated motor frequency (Hz) of the 
second motor.
458
Second motor 
constant (R1)
9999
55K or lower
0 to 50
Ω, 9999
Tuning data of the second motor
(The value measured by offline auto 
tuning is automatically set.)
9999: Use the Mitsubishi motor (SF-JR, 
SF-HR, SF-JRCA, SF-HRCA, SF-V5RU 
(1500r/min series), etc.) constants
75K or higher
0 to 400m
Ω, 
9999
459
Second motor 
constant (R2)
9999
55K or lower
0 to 50
Ω, 9999
75K or higher
0 to 400m
Ω, 
9999
460
Second motor 
constant (L1)
9999
55K or lower
0 to 50
Ω
(0 to 1000mH)
9999
75K or higher
0 to 3600m
Ω
(0 to 400mH)
9999
461
Second motor 
constant (L2)
9999
55K or lower
0 to 50
Ω
(0 to 1000mH)
9999
75K or higher
0 to 3600m
Ω
(0 to 400mH)
9999
462
Second motor 
constant (X)
9999
55K or lower
0 to 500
Ω
(0 to 100%)
9999
75K or higher
0 to 100
Ω
(0 to 100%)
9999
463
Second motor auto 
tuning setting/status
0
0
Second motor auto tuning is not performed
1
Offline auto tuning is performed without 
second motor running
101
Offline auto tuning is performed with 
second motor running
684
Tuning data unit 
switchover
0
0
Internal data converted value
1
Displayed in "A, 
Ω, mH, %"
859
Torque current
9999
55K or lower
0 to 500A
Tuning data
(The value measured by offline auto 
tuning is automatically set.)
75K or higher
0 to 3600A
9999
Use the Mitsubishi motor (SF-JR, SF-HR, 
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series), etc.) constants
860
Second motor torque 
current
9999
55K or lower
0 to 500A
Tuning data of the second motor
(The value measured by offline auto 
tuning is automatically set.)
75K or higher
0 to 3600A
9999
Use the Mitsubishi motor (SF-JR, SF-HR, 
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series), etc.) constants
Parameter 
Number
Name
Initial 
Value
Setting Range
Description