CONNECTION OF REMOTE I/O UNIT 
6.12  Connection of FCUA-DX13 
† Unit and Manual Pulse Generator 
 
 
-
 70
 
6.12  Connection of FCUA-DX13 
† Unit and Manual Pulse Generator 
 
When connecting the manual pulse generator, the R041 or R042 cable is connected to HANDLE. Up to 
two manual pulse generators can be connected. Use the CS000 connector set (optional, with both 
ends) when manufacturing the R041 or R042 cable. 
 
Connecting one manual pulse generator 
 
HANDLE 
FCUA-DX13□ 
1
10
11
 
20
 
Pin No.
Manual pulse generator 
FCUA-HD60 
Rear view 
NO.1 
4-M3
 
R041 cable
12V 0V A  B 
 
 
 
Connecting two manual pulse generators 
 
12V
 0V A 
B
 
HANDLE 
Manual pulse generator
FCUA-HD60 
Rear view 
R042 cable
NO.2 
SEL*
 
NO.1
4-M3
When connecting the second manual pulse generator, 
connect the SEL* signal to the No.1, 0V.
 
FCUA-DX13†
12V 0V A  B 
12V 0V A  B
 
 
 
 CAUTION 
 
  Incorrect connections could damage the device, so always connect the cable to the 
designated connector. 
 
  Do not connect or disconnect the connection cables between each unit while the power 
is ON.