May 1998
Install and Cable the Cabinets 
Page 1-58
Install and Wire Telephones and Other Equipment 
1
Analog Station or 2-Wire Digital Station Example
This example is typical of the 2-wire digital stations,2-wire analog stations, analog 
CO trunks, DID trunks, and external alarms. See 
Figure 1-27
.
Figure 1-27.
2500-Type Analog Telephone Wiring
1. Choose a peripheral to connect (such as a 2-wire digital station).
2. Choose the port circuit pack to use and its carrier and slot number. For 
example, TN2183 Analog Line, Cabinet 1, Carrier C, Slot 1. 
3. Choose a port circuit on the port circuit pack, for example port 3.
4. Install cross-connect jumpers to connect the pins from the 2-wire station to 
the appropriate pins on the port circuit pack. 
5. Administer using 
DEFINITY Enterprise Communications Server Release 6 
Administration and Feature Description
.
Figure Notes
1. 2500-type analog station
2. 2-wire analog line circuit pack
2500wire RBP 040596
3
28
03
2
T
R
T3
R3