Lucent Technologies 555-230-128 User Manual

Page of 144
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets  
555-230-128  
Issue 3
May 1998
Install and Cable the Cabinets 
Page 1-59
Install and Wire Telephones and Other Equipment 
1
Analog Tie Trunk Example
Figure 1-28.
Analog Tie Trunk Wiring
1. Before installing the Tie Trunk circuit pack, set the option switches as 
described in 
Chapter 2, ‘‘Installation Completion and Cable Pinouts’’
.
2. Install cross-connect jumpers to connect the pins from the Tie Trunk circuit 
pack to the appropriate leads on the external tie trunk. Names of the tie 
trunk leads must be determined from the manufacturer or supplier of the 
external trunk circuit. The example in 
Figure 1-28
 shows a DEFINITY 
System tie trunk connected to a DEFINITY System tie trunk. 
3. Administer on the Trunk Group Screen. See 
DEFINITY Enterprise 
Communications Server Release 6 Administration and Feature 
Description
.
Figure Notes
1. External trunk or adapter
2. Tie trunk circuit pack
tie_wire RBP 040596
1
27
26
29
4
30
5
2
28
3
31
6
T1
R1
T11
R11
E1
M1
T2
R2
T12
R12
E2
M2