Install and Cable the Cabinets 
Page 1-62
Install and Wire Telephones and Other Equipment 
1
DS1 Tie Trunks Using T1 Channel Service Unit
Figure 1-30
 shows a DS1 tie trunk connected to an external T1 Channel Service 
Unit (CSU). A 120A2 enhanced Integrated Channel Service Unit (ICSU) can be 
used in place of a T1 external CSU. The CSU or ICSU interfaces the DS1 tie 
trunks with the 1.544 Mbps digital facility. Contact your Lucent Technologies 
representative for maximum cabling distances.
Figure 1-30.
Typical Connections to Channel Service Unit
Figure Notes
1. To DS1 tie trunk circuit pack
2. C6C cable (If distance is over 50 
feet (15.24 m), use C6E cable.)
3. T1 external CSU or 120A2 ICSU
4. Tip (T)
5. Ring (R)
6. Tip 1(T1)
7. Ring1 (R1)
8. 1.544 Mbps T1 interface
9. To T1 carrier