Lucent Technologies 555-230-128 User Manual

Page of 144
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets  
555-230-128  
Issue 3
May 1998
Install and Cable the Cabinets 
Page 1-61
Install and Wire Telephones and Other Equipment 
1
DS1 Tie Trunk Example
DS1 tie trunks provide a 1.544 Mbps (T1) or 2.048 Mbps (E1) digital data service 
between 2 collocated systems or between the system and a data network. The 
following cables can be used:
C6C connector cable 
 50-foot (15.2 m) shielded cable with a 50-pin 
male connector on 1 end and a 15-pin male connector on the other end. 
Use to connect a DS1 tie trunk circuit pack to a Channel Service Unit.
C6D connector cable 
 50-foot (15.2 m) shielded cable with a 50-pin 
male connector on each end. Use to connect a DS1 tie trunks in 
collocated cabinets.
C6E connector cable 
 100-foot (30.5 m) shielded cable with a 50-pin 
male connector on 1 end and a 50-pin female connector on the other end. 
Use as an “extension” cable between the DS1 tie trunk circuit pack and 
other connector cables.
C6F connector cable 
 50-foot (15.2 m) shielded cable with a 50-pin 
male connector on 1 end and a 3 inch (7.62 cm) stub on the other end. 
Use to connect the DS1 tie trunk circuit pack to channel multiplexers 
requiring hardwired connections. See 
Table 1-8
 for a pinout.
Collocated DS1 Tie Trunks
Two DS1 tie trunk circuit packs can be in collocated systems. A DS1 tie trunk 
circuit pack in 1 system can connect to a DS1 tie trunk in another system. Use a 
C6D cable if the distance is less than 50 feet (15.24 m). If the distance is greater 
than 50 feet (15.24 m), use a C6E cable.
NOTE:
The maximum distance between cabinets is 1310 feet (399.3 m).
Table 1-8.
Pinout of C6F Cable
Wire Color
Lead Designation
Pin 
Number
White/Green
L
I
 (High Side)
47
Green
L
I
22
White/Brown
LO
48
Brown
LO (High Side)
23
White/Slate
LBACK2
49
Slate
LBACK1
24