Figure 23 - Correct Pilot Flame Pattern 
Millivolt Assembly
Figure 24 - Correct Pilot Flame Pattern 
Electronic Assembly
Figure 26 - Air Shutter Adjustment
Burner Pan
Air Shutter 
Screw
Orifice
Gas Valve
3/8" to 1/2"
1/8" to 1/4"
Pilot 
Burner
Ignitor
Flame 
Sensor 
Pan 
Burner
3/8" to 1/2"
(10 mm - 13 mm)
1/8" (3 mm)
Ignitor
Pilot Burner
Thermopile
CORRECT
INCORRECT
CLOSE 
SHUTTER
INCORRECT
OPEN
SHUTTER
LONG, BLUE FLAME
WITH YELLOW TIPS
SHORT, SHARP
BLOWING FLAME
LONG, UNEVEN
YELLOW FLAME
Figure 25 - Burner Flame Patterns
INSPECTING BURNER
PILOT ASSEMBLY ADjUSTMENT
The pilot assembly is factory preset for the proper 
flame height. Alteration to factory settings may 
have occurred during shipping. If this is the case, 
some minor readjustments may be necessary and 
should be done by a qualified technician.
The pilot assembly is located behind the burner 
next to the rear refractory piece at the right-hand 
side. The thermopile (in millivolt models) or the 
sensor (in electronic models) should be engulfed 
with the pilot flame approximately 3/8" to 1/2" in 
order for the regulator to receive proper signal (see 
Figures 23 and 24).
BURNER FLAME ADjUSTMENT
The air shutter, located at the base of the main 
burner tube, has been factory preset to the proper 
air to gas ratio which results in an even, clean burn-
ing flame across the burner (see Figure 25).
If readjustment is necessary, you can restore proper 
flame setting by loosening air shutter screw and 
rotate air shutter until proper flame setting is 
achieved (shutters normal setting is fully opened).  
Retighten air shutter screw. See Figure 26 for air 
shutter location.
CAUTION: Make certain ori-
fice is fully inside venturi tube’s
air shutter and that air shutter is 
adjusted accordingly.