Desa GL36CL User Manual

Page of 20
www.desatech.com
112301-01D
15
SPECIFICATIONS
(V)GL36CR, (V)GL36CRE, (V)GL36CL,
(V)GL36CLE
•  Maximum Input Rating at Altitudes: 0-2,000 ft. - 
42,000 Btu/hr., 2,000-4,000 ft. - 37,800 Btu/hr.
•  Manifold Pressure: 3.5 W.C. (.87 kPa)
•  Supply Pressure (in. of water): Minimum* - 4.5" 
(1.12 kPa), Maximum - 11.0" (2.74 kPa)
•  Orifice Size at Altitudes: 0-2,000 ft. - #30,  
2,000-4,000 ft. - #31
(V)GL36CRP, (V)GL36CRPE, (V)GL36CLP,
(V)GL36CLPE
•  Maximum Input Rating at Altitudes: 0-2,000 ft. - 
42,000 Btu/hr., 2,000-4,000 ft. - 37,800 Btu/hr.
•  Manifold Pressure: 11.0 W.C. (2.74 kPa)
•  Supply Pressure (in. of water): Minimum* - 
12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)
•  Orifice Size at Altitudes: 0-2,000 ft. - #49,  
2,000-4,000 ft. - #51
* For the purpose of input adjustment
DO NOT
CONNECT
N.C.SW
HEAT LIMIT SWITCH
TH/TP
TP
TH
WALL SWITCH
(SUPPLIED)
TO 120V
THERMOPILE
PILOT
IGNITOR
O
F F
PI
L
O
T
ON
PILOT SAFETY WIRE
MAIN GAS
INCOMING
SUPPLY
MILLIVOLT WIrING DIAGrAM
ELECTrONIC WIrING DIAGrAM
WIRING DIAGRAMS
STEP DOWN 
TRANSFORMER 
EV2 
SUPPLY 
INCOMING 
MAIN GAS 
EV1 
TO 
GAS LINE
 BURNER
24V AC 
N.C.SW 
HEAT LIMIT  
SWITCH 
120V AC 
120V AC 
INCOMING 
OR BREAKER) 
(FUSE BOX 
OFF 
ON 
(SUPPLIED) 
USE ONLY CL2 THRMST WIRE
18 GA. RED/WHT (PROVIDED)
OR EQUIVALENT
WALL SWITCH 
GREEN 
BLACK 
WIREW
A
Y
WHITE 
120v, 60Hz, 0.7A
ELECTRICAL RATING:
BLACK 
CONNECTORS 
(NOT SUPPLIED)
FIELD WIRE
WHITE 
GREEN 
OPTIONAL 
REMOTE 
CONTROL 
SENSOR
PILOT
IGNITOR
 
P
V
 
G
N
D
 
PV
/M
V T
R
 
M
V
 
TH
 
IG
N