Mitsubishi Electronics FX3G User Manual

Page of 964
458
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
16 External FX Device – FNC 80 to FNC 89
16.2 FNC 81 – PRUN / Parallel Run (Octal Mode)
16.2
FNC 81 – PRUN / Parallel Run (Octal Mode)
Outline
This instruction handles the device number of 
 with digit specification and the device number of 
 as octal
numbers, and transfers data.
1. Instruction format
2. Set data
*1.
Make sure that the least significant digit of a specified device number is "0".
3. Applicable devices
Explanation of function and operation
1. 16-bit operation (PRUN and PRUNP)
Octal bit device 
 Decimal bit device
Operand type
Description
Data type
Digit specification
*1
16- or 32-bit binary
Device number of transfer destination
*1
16- or 32-bit binary
Oper-
and 
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special 
Unit
Index
Con-
stant
Real 
Number
Charac-
ter String
Pointer
X Y M T C S D .b KnX KnY KnM KnS T C D R U \G
V Z Modify K H
E
" "
P
   
S
   
D
DPRUN
DPRUNP
Mnemonic
Operation Condition
P
FNC 81
PRUN
D
16-bit Instruction
5 steps PRUN
PRUNP
Mnemonic
Operation Condition
Continuous
Operation
Pulse (Single)
Operation
32-bit Instruction
9 steps
Continuous
Operation
Pulse (Single)
Operation
S
1
 ‚
  S
  D
S
1
 ‚
  S
S
2
 ‚
  D
Command
input
FNC 81
PRUN
K4X000
K4M0
X000 to X017 
→ M0 to M7, M10 to M17
Octal bit device (X)
X17 X16 X15 X14 X13 X12 X11 X10 X7
X6
X5
X4
X3
X2
X1
X0
M15 M14 M13 M12 M11
M9 M8 M7 M6 M5 M4
M3 M2 M1 M0
M17 M16
M10
M8 and M9 do not change
Decimal bit device (M)