Programming Manual - Basic & Applied Instruction Edition
2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
7
Setting the PLC system (1)
Click on the [PLC System(1)] tab to setup "Battery Less Mode", "Battery Mode", "MODEM Initialized", and
"RUN Terminal Input".
1) FX
3S
/FX
3U
/FX
3UC
 PLC
2) FX
3G
/FX
3GC
 PLCs
*1.
This area can be set only in FX
3U
/FX
3UC
 PLCs.
*2.
This area can be set only in FX
3G
/FX
3GC
 PLCs.
*3.
Up to the built-in input number of main unit.
Set item
Contents of setting
Setting range
Battery Less Mode
*1
Select this to operate the PLC without using the battery.
When a check mark is put here, the battery error indicator lamp is automatically 
turned off and devices in the latched (battery backed) area are automatically 
cleared.
Battery Mode
*2
Select this item to operate the PLC with the battery.
MODEM Initialized
Set this item to automatically initialize a connected modem when the PLC power 
is turned ON.
RUN Terminal Input
Set this item to use an input terminal (X) to switch the PLC between STOP and 
RUN.
None
X000 to X017
*3