Mitsubishi Electronics FX3G User Manual

Page of 964
89
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
4 Devices in Detail
4.2 I/O Relays [X, Y]
1
Introdu
ction
2
Ov
ervi
ew
3
Instruction 
Li
st
4
D
evices 
in Det
ai
l
5
Specifi
ed the
De
vice
 &
 
C
onst
ant
6
Bef
ore
 
Pr
og
ra
mmi
ng
7
Bas
ic 
Instruction
8
FN
C00-FN
C0
9
Program Fl
ow
9
FNC
10-FN
C19
Mov
e & Com
pare
10
FNC
20-FNC
29
Arith. & Lo
gi
Operati
on
4.2
I/O Relays [X, Y]
Some input relays and output relays are secured in the main unit, and others are assigned to extension devices
according to the connection order. Because I/O replays are numbered in octal, numeric values such as "8" and "9" do
not exist.
4.2.1
Numbers of I/O relays
The table below shows input relay (X) and output relays (Y) numbering (Relay numbers are assigned in octal.
)
*1.
A number inside (  ) indicates the number of occupied points. The difference from the number of valid points is
unused.
FX
3S
PLC
Model 
name
FX
3S
-10M
FX
3S
-14M
FX
3S
-20M
FX
3S
-30M
30 
points in 
total
Input
X000 to X005
6 points
X000 to X007
8 points
X000 to X013
12 points
X000 to X017
16 points
Output
Y000 to Y003
4 points
Y000 to Y005
6 points
Y000 to Y007
8 points
Y000 to Y015
14 points
FX
3G
PLC
Model 
name
FX
3G
-14M
FX
3G
-24M
FX
3G
-40M
FX
3G
-60M
When extended
128 
points in 
total
Input
X000 to X007
8 points
X000 to X015
14 points(16)
*1
X000 to X027
24 points
X000 to X043
36 points(40)
*1
X000 to X177
128 points
Output
Y000 to Y005
6 points(8)
*1
Y000 to Y011
10 points(16)
*1
Y000 to Y017
16 points
Y000 to Y027
24 points
Y000 to Y177
128 points
FX
3GC
PLC
Model 
name
FX
3GC
-32MT/
D(SS)
When extended
128 
points in 
total
Input
X000 to X017
16 points
X000 to X177
128 points
Output
Y000 to Y017
16 points
Y000 to Y177
128 points
FX
3U
PLC
Model 
name
FX
3U
-16M
FX
3U
-32M
FX
3U
-48M
FX
3U
-64M
FX
3U
-80M
FX
3U
-128M
When 
extended
256 
points in 
total
Input
X000 to X007
8 points
X000 to X017
16 points
X000 to X027
24 points
X000 to X037
32 points
X000 to X047
40 points
X000 to X077
64 points
X000 to X367
248 points
Output
Y000 to Y007
8 points
Y000 to Y017
16 points
Y000 to Y027
24 points
Y000 to Y037
32 points
Y000 to Y047
40 points
Y000 to Y077
64 points
Y000 to Y367
248 points
FX
3UC
 (D, DS, DSS) PLC
Model 
name
FX
3UC
-16M
FX
3UC
-32M
FX
3UC
-64M
FX
3UC
-96M
When 
extended
256 
points 
in total
Input
X000 to X007
8 points
X000 to X017
16 points
X000 to X037
32 points
X000 to X057
48 points
X000 to X367
248 points
Output
Y000 to Y007
8 points
Y000 to Y017
16 points
Y000 to Y037
32 points
Y000 to Y057
48 points
Y000 to Y367
248 points
FX
3UC
-32MT-LT(-2) PLC
Model 
name
FX
3UC
-32MT-LT 
(-2)
When extended
256 
points in 
total
Input
X000 to X017
16 points
X000 to X357
240 points
Output
Y000 to Y017
16 points
Y000 to Y357
240 points