HV-G Instruction Manual Page 37
Caution
The parameters of the upper limit value (HI) and a final value (HI) use the same
memory. The parameters of the lower limit value (LO) and the zero band (LO) use
the same memory.
The upper/lower comparator function, the simple batch function and the full/dribble
batch function cannot be used at the same time because these parameters use
common memory.
13.1 Preparation (Setting Parameters)
Step 1 Turn off the display.
Press the  
ON/OFF
  switch while the  
ZERO
  switch
is  pressed and held. The function table is displayed.
Step 2 Press the 
 ENTER 
 switch to display an item of the
comparator function ( 
 f6 
 ).
Step 3 Select a parameter of the simple batch function
 f6 8 
 ) with the 
 
^
 
 switch.
Step 4 Press the 
 ENTER 
 switch to store the new
parameter.
Step 5
Press the  
F
  switch and the  
ENTER
  switch to exit
from the function table. Then the scale displays the
weighing mode.