Lenovo 3000 V100 User Manual

Page of 66
Code
 
Message
 
Description
 
02B0
02B1
 
Diskette
 
drive
 
A
 
error
Diskette
 
drive
 
B
 
error
 
Drive
 
A:
 
or
 
B:
 
is
 
present
 
but
 
fails
 
the
 
BIOS
 
POST
 
diskette
 
tests.
 
Check
 
to
 
see
 
that
 
the
 
drive
 
is
 
defined
 
with
 
the
 
proper
 
diskette
 
type
 
in
 
Setup
 
and
 
that
 
the
 
diskette
 
drive
 
is
 
attached
 
correctly.
 
02B2
 
Incorrect
 
Drive
 
A
 
type
 
-
 
run
 
SETUP
 
Type
 
of
 
floppy
 
drive
 
A:
 
not
 
correctly
 
identified
 
in
 
Setup.
 
02B3
 
Incorrect
 
Drive
 
B
 
type
 
-
 
run
 
SETUP
 
Type
 
of
 
floppy
 
drive
 
B:
 
not
 
correctly
 
identified
 
in
 
Setup.
 
02F0
 
CPU
 
ID
 
CPU
 
socket
 
number
 
for
 
Multi-Processor
 
error.
 
02F4*
 
EISA
 
CMOS
 
not
 
writable
 
ServerBIOS2
 
test
 
error:
 
Cannot
 
write
 
to
 
EISA
 
CMOS.
 
02F5*
 
DMA
 
Test
 
Failed
 
ServerBIOS2
 
test
 
error:
 
Cannot
 
write
 
to
 
extended
 
DMA
 
(Direct
 
Memory
 
Access)
 
registers.
 
02F6*
 
Software
 
NMI
 
Failed
 
ServerBIOS2
 
test
 
error:
 
Cannot
 
generate
 
software
 
NMI
 
(Non-Maskable
 
Interrupt).
 
02F7*
 
Fail
 
-
 
Safe
 
Timer
 
NMI
 
Failed
 
ServerBIOS2
 
test
 
error:
 
Fail-Safe
 
Timer
 
takes
 
too
 
long.
 
N/A
 
Device
 
Address
 
Conflict
 
Address
 
conflict
 
for
 
specified
 
device.
 
N/A
 
Allocation
 
Error
 
for
 
:
 
device
 
Run
 
ISA
 
or
 
EISA
 
Configuration
 
Utility
 
to
 
resolve
 
resource
 
conflict
 
for
 
the
 
specified
 
device.
 
N/A*
 
Failing
 
Bits:
 
nnnn
 
The
 
hex
 
number
 
nnnn
 
is
 
a
 
map
 
of
 
the
 
bits
 
at
 
the
 
RAM
 
address
 
which
 
failed
 
the
 
memory
 
test.
 
Each
 
1
 
(one)
 
in
 
the
 
map
 
indicates
 
a
 
failed
 
bit.
 
See
 
errors
 
230,
 
231,
 
or
 
232
 
above
 
for
 
offset
 
address
 
of
 
the
 
failure
 
in
 
System,
 
Extended,
 
or
 
Shadow
 
memory.
 
N/A
 
Invalid
 
System
 
Configuration
 
Data
 
Problem
 
with
 
NVRAM
 
(CMOS)
 
data.
 
N/A
 
I/O
 
device
 
IRQ
 
conflict
 
I/O
 
device
 
IRQ
 
conflict
 
error.
 
N/A
 
One
 
or
 
more
 
I2O
 
Block
 
Storage
 
Devices
 
were
 
excluded
 
from
 
the
 
Setup
 
Boot
 
menu
 
There
 
was
 
not
 
enough
 
room
 
in
 
the
 
IPL
 
table
 
to
 
display
 
all
 
installed
 
I2O
 
block-storage
 
devices.
 
N/A
 
Operating
 
system
 
not
 
found
 
Verify
 
the
 
following:
 
The
 
hard
 
disk
 
drive
 
is
 
correctly
 
installed.
 
A
 
startable
 
diskette
 
is
 
in
 
the
 
diskette
 
drive.
 
If
 
you
 
still
 
see
 
the
 
same
 
error
 
message,
 
check
 
the
 
boot
 
sequence
 
using
 
BIOS
 
Utility.
 
N/A*
 
Parity
 
Check
 
1
 
nnnn
 
Parity
 
error
 
found
 
in
 
the
 
system
 
bus.
 
BIOS
 
attempts
 
to
 
locate
 
the
 
address
 
and
 
display
 
i
 
on
 
the
 
screen.
 
If
 
it
 
cannot
 
locate
 
the
 
address,
 
it
 
displays
 
????.
 
Parity
 
is
 
a
 
method
 
for
 
checking
 
errors
 
in
 
binary
 
data.
 
A
 
parity
 
error
 
indicates
 
that
 
some
 
data
 
has
 
been
 
corrupted.
 
Solving
 
computer
 
problems
 
12
 
Lenovo
 
3000
 
V100
 
Service
 
and
 
Troubleshooting
 
Guide