7.  Servo Parameters  
7.4  Supplement 
 
171 
 
(Continued from the previous page) 
No. Output 
data 
Standard output 
unit 
Standard setting 
value of output 
scale 
(Setting values in 
SV063, SV064) 
Standard 
output unit 
Output
cycle 
77 
Estimated disturbance 
torque 
Internal unit 
(adjustment 
required) 
– 888µs 
 
 
 
 
 
 
125 
Saw-tooth wave test 
output 
0V to 5V 
0 (256) 
Cycle: 227.5ms
888µs 
126 
Rectangular wave test 
output 
0V to 5V 
0 (256) 
Cycle: 1.7ms 
888µs 
127 
2.5V (data 0) test 
output 
2.5V 0 
(256)  – 
888µs 
 
 
 
(c)  Setting the output scale 
 
# No. 
Abbrev Parameter 
name 
2263 
SV063 
DA1MPY 
D/A output channel 1 
output scale 
2264 
SV064 
DA2MPY 
D/A output channel 2 
output scale 
 
Usually, the standard setting value is set for the output scale (SV063, SV 064).  When “0” is set, 
the output will be made as well as when “256”  is set. 
 
SV063
5 [V] 
DATA x 
256 
256 (8bit)
+ 2.5 [V] (offset) = Output voltage [V] 
 
(Example) When outputting the current FB with 100%/V–stall  (SV061=3, SV063=131) 
 
131 5 
100 x 
256 
256 
+ 2.5 = 3.499 [V]