Graco 257500 User Manual

Page of 24
Troubleshooting 
16
313879B
Troubleshooting
Problem
Cause
Solution
Kettle pilot burner does 
not ignite or does not 
remain ignited
Low or empty LP-gas tank
Replace with full tank.
Gas supply hose not connected to tank
Connect gas supply hose.
LP-gas tank shut-off valve closed
Open LP-gas tank shut-off valve.
Manual gas shut-off valve closed
Open manual gas shut-off valve.
Gas lines leaking or disconnected
Check for gas leaks. Connect and tighten 
fittings.
Kettle gas safety valve knob not in correct 
position
Turn knob to “PILOT” position and fully 
push in (see Operation manual).
Not providing adequate time for thermopile to 
heat up
See Operation manual.
Kettle pilot igniter has weak battery
Replace part (see Parts manual).
Kettle pilot electrode gap incorrect
Adjust gap (see page 7).
Incorrect flame length and/or gas pressure
Adjust flame and pressure (see Repair 
manual).
Strong wind blowing flame out
Move ThermoLazer
 out of strong winds. 
Make sure burner view ports are closed.
Burner and/or gas lines plugged
Unplug holes and lines. Isolate all gas reg-
ulators if clearing line with forced air (see 
page 5).
Kettle gas safety valve not functioning cor-
rectly
Replace part if it fails diagnostic test (see 
page 5).
Thermopile not functioning correctly
Replace part if it fails diagnostic test (see 
page 8).
Kettle pilot electrode ground wire not correctly 
connected
Clean connections and retighten. Replace 
ground wire if damaged.
Kettle pilot electrode lead wire has a short
Replace part (see Parts manual).
Kettle pilot igniter not functioning correctly
Replace part (see Parts manual).
Kettle burner regulator not functioning cor-
rectly
Replace part (see Parts manual).