Graco 257500 User Manual

Page of 24
Troubleshooting
313879B
17
Kettle main burners do 
not ignite or are not 
burning correctly
Kettle gas safety valve knob not at correct 
position
Turn knob to ON position (see Operation 
manual).
Kettle temperature control dial set at a lower 
temperature than material temperature
Turn kettle temperature control dial to tem-
perature 25° F (13.9° C) higher than mate-
rial temperature.
Kettle gas safety valve not functioning cor-
rectly
See Repair manual and replace part if it 
fails diagnostic testing.
Burner and/or gas lines plugged
Unplug holes and lines. Isolate all gas reg-
ulators if clearing line with forced air (see 
page 12).
Kettle temperature control not functioning cor-
rectly
Replace part (see Parts manual).
Gas lines have been disconnected 
Connect and tighten hose fittings. Check 
for gas leaks.
Incorrect flame length and/or gas pressure
Adjust flame and pressure (see page 11).
Kettle gas safety valve knob not at correct 
position
Replace part (see Parts manual).
Kettle main burners do 
not shut off
Kettle temperature control dial is not turned to 
a setting lower than material temperature
Turn kettle temperature control dial to a 
setting 25° F (13.9° C) (minimum) lower 
than material temperature.
Kettle temperature control not functioning cor-
rectly
Replace part (see Parts manual).
Kettle gas safety valve not functioning cor-
rectly
Replace part if it fails diagnostic testing 
(see page 5)
Kettle main burner does 
not turn on
Kettle temperature control dial is not turned to 
a setting higher than material temperature
Turn kettle temperature control dial to a 
setting 25° F (13.9° C) (minimum) higher 
than material temperature.
Kettle temperature control not functioning cor-
rectly
Replace part (see Parts manual).
Kettle gas safety valve not functioning cor-
rectly
Replace part if it fails diagnostic test (see 
page 5).
Thermometer not 
matching material tem-
perature in kettle
Material has not reached temperature control 
set point
Allow time for material to reach operating 
temperature.
Material not fully obligated
Agitate material.
Cool or windy ambient conditions
Move ThermoLazer
 out of cool windy 
conditions. Discharge material and check 
thermometer.
Thermometer calibrated incorrectly
Calibrate thermometer (see page 7).
Kettle temperature control calibrated incor-
rectly
See Repair manual and replace part if it 
can not be calibrated. See Parts manual 
313880.
Thermometer not functioning correctly
Replace part (see Parts manual).
Kettle temperature control not functioning cor-
rectly
Replace part (see Parts manual).
Kettle gas safety valve not functioning cor-
rectly
Replace part if it fails diagnostic test (see 
page 5).
Incorrect flame length and/or gas pressure
Adjust flame and pressure (see page 11).
Problem
Cause
Solution