Operating the Temperature Control System
Water Temperature Adjustment
The water temperature can be adjusted from 110°F to 
150°F. Turn the Gas Control/Temperature Knob to the 
desired setting/temperature.
Operating Modes and Settings
• 
Standard Mode - The controller adjusts the water 
heater to maintain the temperature set by the user.
• 
Energy Smart Mode - The controller adjusts the water 
temperature to the lowest temperature required to 
meet the household demands. This mode minimizes 
operating costs. The controller will not adjust the 
temperature higher than the user’s selected set point or 
lower than 115°F.
• Vacation 
Setting - The controller adjusts the water 
temperature to approximately 80°F. This setting is 
recommended when the water heater is not in use for 
a long period of time. This effectively turns the water 
heater down to a setting that prevents the water from 
freezing.
Diagnostic Status Light Code
No status light indicates a control off or the pilot is out.
Standard Flashes:
1 Flashes   Indicates Normal Operation
2 Flashes   Indicates Thermopile Voltage Low
3 Flashes   Indicates Valve or Sensor Failure
Flashes 
 Indicates 
Overheat 
Failure         
5 Flashes   Indicates Lower Sensor Failure
6 Flashes   Indicates Upper Sensor Failure
7 Flashes   Indicates Electronic Control Failure
8 Flashes   Indicates Valve Failure
Continuous Solid Flash indicates system shutdown
NOTE: If the pilot lights, but will only stay lit with the knob 
depressed in the pilot position, look for the following status 
light codes.
6 Second Solid Light followed by:
4 Flashes 
The unit will not relight because it detects an 
overheat failure. 
7 Flashes 
The unit will not relight because it detects an 
electronic control failure.
8 Flashes 
The unit will not relight because it detects a 
valve failure.
6 Second Solid Light with combinations of:
4 + 7 Flashes* 
The unit will not relight because it 
detects an overheat failure and an 
electronic control failure. 
4 + 8 Flashes* 
The unit will not relight because it 
detects an overheat failure and a valve 
failure.
7 + 8 Flashes* 
The unit will not relight because it 
detects an electronic control failure and 
a valve failure.
4 + 7 + 8 Flashes*  The unit will not relight because 
it detects an overheat failure, an 
electronic control failure and a valve 
failure.
* Flashes are displayed at 1 second apart and a 3 second 
pause between combinations.
Figure 19B
Temperature Control System
STATUS LIGHT CODE
Flashes are displayed 1 second apart at 3 second intervals
STATUS LIGHT CODE
Flashes are displayed 1 second apart at 3 second intervals
120°
Mark
120°
Mark
150°
Mark
Index
Mark