ECO G 3 Way Outdoor Unit Specifications
ECO G 3 Way Heat Recovery VRF System
LPG option
The option of using LPG as a power supply increases flexibility 
and  avoids  the  problems  of  potential  site  restrictions  in  the 
future.  The  purer  fuel  is  also  excellent  for  further  reductions 
in CO
2
 emissions - a fact recognised by the government.
Still the only heat recovery (3 way) GHP system in 
Europe. 
The  new  M  Series  ECO  G  3  Way  offers  even  more 
performance  and  outstanding  features  when  you  need 
simultaneous  heating  and  cooling.  Now  with  increased 
capacities available from 16HP to 25HP, SANYO offers the 
greatest choice and flexibility to solve any power problem or  
site requirement.
• Simultaneous heating and cooling for total control
• Reduced gas consumption by Miller-cycle engine
•  Reduced electrical power consumption by using DC motors
•  New  lightweight  design  by  use  of  aluminium  engine  block 
reduces weight by 110kg
• Part load efficiencies increased
• Connectability increased to up to 36 indoor units
• Now available in 16, 20 and 25HP
• 200m maximum allowable piping length (L1) (equivalent - refer 
to technical manual)
• Diversity ratio 50% - 130%
• Extended pipe runs (total 500m)
• Silent mode offers a further 2dB(A) reduction
•  10,000 run hours between engine service intervals (equivalent 
to one maintenance every 3.2 years*)
• Full heating capacity down to -20°C
• No defrost cycle
* Assuming 3120 running hrs per year - 12 hrs x 5 days x 52 weeks
ECO G 3 Way is ideal for the following types of 
application:
•  Office  buildings  with  a  diverse  range  of  room  temperatures 
due to differing load profiles.
•  Buildings with computer rooms requiring year round cooling.
Additional parts
By  taking  its  power  supply  from  the  nearest  indoor  unit,  the 
SANYO solenoid valve (change-over box) does not require any 
additional  fused  spur  and  at  only  150mm  high  can  be  easily 
installed within a 200mm void space.
Dimensions ECO G 3 Way (16-25HP)
Comparison of the start times for heating operation
Room temperature (˚C )
Gas heat pump
Electric heat pump
Time axis (in case of the same load)
Outside air temperature (˚C)
Electric heat pump
Gas heat pump
Comparison of heating capacity
Heating capacity (% )
Comparison of the start times for heating operation
Room temperature (˚C )
Gas heat pump
Electric heat pump
Time axis (in case of the same load)
Outside air temperature (˚C)
Electric heat pump
Gas heat pump
Comparison of heating capacity
Heating capacity (% )
HP
16
20
25
Model
SGP-EZ150M2G2
SGP-EZ190M2G2
SGP-EZ240M2G2
Capacity
Cooling
kW
45.0
56.0
71.0
Heating 
STD
kW
50.0
63.0
80.0
Heating  Low temp*
53.0
67.0
75.0
Electricity
Cooling
kW
1.35
Heating
kW
1.01
1.54
Gas 
Cooling
kW
31.6
38.3
60.9
Heating 
STD
kW
36.1
43.0
58.0
Heating 
LOW
47.3
56.4
64.9
COP
Cooling
1.37
1.41
1.14
Heating
1.35
1.43
1.34
AVE
1.36
1.42
1.24
Size
Height
mm
2,248
Width
1,800
Depth
1,000 (+60)
Weight
kg
845
875
Starter amperes
A
30
Piping 
connection
Gas
Inches (mm)
1 1/8 (28.58)
Discharge
7/8 (22.22)
Liquid
3/4 (19.05)
Pipe fuel gas
R3/4 (bolt thread)
Pipe exhaust drain
mm
ø 25 rubber hose
Operation sound
dB(A)
57
58
62
Indoor/outdoor capacity ratio
50-180% *1
Number of indoor connections
36
* 1: Low temp condition: Outdoor temperature 2 C˚. 
Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. 
Please refer to tube sizing charts for pipe selections and pipe length parameters.
Rear View
Front View
Left Side View
at least 2000
Service Clearances for installation
(Units: mm)
Rear
(refrigerant tubing)
Rear
(refrigerant tubing)
at
 le
as
60
0
at
 le
as
60
0
at
 le
as
10
00
at
 le
as
10
00
at least 
100
at least 
100
at least 
100
at least 
350
at least 
350
Front View
Front View
(Single-unit installation)
(Multi-unit series installation)
Suction refrigerant pipe
ø28.58
ø22.22
Size (mm)
Model Type
150
190   240
ø25.4
ø19.05
ø28
ø28
G: R3/4
ø20
4 - ø20
4 - ø24
OD: ø25 Length: 200
1
Discharge refrigerant pipe
2
Liquid refrigerant pipe
3
Exhaust gas drain hose
4
Inter-unit cable port
5
Electrical power supply port
6
Fuel gas port
7
Condensation drain opening
8
Rain and condensation outlet
9
Engine exhaust outlet
10
Suspension holes
11
Anchor holes
12
Segmented display
13
Coolant intake (top)
14
Vent
15
Top View
1800 (external)
22
48
 (+
30
)
(1
81
)
400
10
14
(a
nc
ho
r p
itc
h)
1000
(anchor pitch)
10
14
12
13
1030 (suspension holes)
1000 (external)
ø736
1060 (frame width)
9
15
11
27
54
147
22
99
10
8
18
1
57
207
242
279
312
55
5
271
7
6
5
4
3
1
2
8