Empire Comfort Systems DVX36DP31(N,P)-1 User Manual

Page of 72
25613-0-0309
Page 36
INSTALLATION
1.   Unpack vent components and check that all items are included.
2.   Check to see that the vent spacer springs are located around the 
flue vent at 8" and 12" intervals along its length.  See Figure 55. 
If not, stretch the spacer springs to about 15" long and wrap them 
around the flue, then interlock the ends of each spring about 2". 
See Figure 56. Maintain equal distance between spring spacers.
3.  Use existing 8" diameter inlet collar to attach outer vent pipe.
4.  Install the Wall Firestop/Thimble assembly as required through 
the wall. Refer to the venting charts in the fireplace manual to 
determine the proper height and size of the vent opening. The 
minimum opening should be 10" wide by 12" high. The minimum 
combustible clearance from the horizontal vent is 1" from sides 
and bottom, and 3" above the vent pipe. See Figure 56.
5.  In most cases, after determining the length of the vent that is 
needed, it may be easier to install the flue and outer vent pipes to 
the Termination Cap first, then from the outside, feed the venting 
through the wall to the fireplace.
6.  If the venting is to long, trim off any excess vent before attaching 
the vent end connectors.
7.  Attach the Termination Cap to the outside of the house.
8.  Prior  to  making  the  vent  connections,  apply  high  temperature 
sealant  (1000  degree  F  min.)  to  the  vent  connections  before 
securing with the band clamps provided. Note: the flue pipe end 
without the adapter is to be installed to the Termination Cap.
9.  Apply sealant to the outside of the flue pipe adapter and connect 
to the flex flue pipe. Then insert the adapter into the fireplace 
flue. Secure flue adapter to the fireplace flue with a minimum of 
two screws provided. See Figure 57.
10.  Attach  the  Outer  Vent  pipe  to  the  8"  diameter  collar  on  the 
fireplace with a large band clamp provided. Sealant may also be 
used on the outer vent connections.
11.   Check all vent connections for tightness. Make sure horizontal 
venting has the proper rise and combustible clearances required. 
Refer to venting charts in fireplace instruction manual.
8” DIA. FLEX
VENT PIPE
5” DIA. FLEX
FLUE PIPE
5” DIA. FLUE
ADAPTOR
COLLAR
8” DIA. INLET
ADAPTOR COLLAR
(WITH GASKET)
BAND CLAMP
APPLY HIGH
TEMPERATURE
SEALANT
Flex venting can only be installed vertically off of the DVX Series fireplaces.  When installing a horizontal vent run from top connec-
tions, maintain at least ½" rise for every 12" of vent run. Refer to the Figure 54 when mounting termination near vinyl siding.
CAUTION: Always stretch and secure venting with wire or metal strapping to ensure that the horizontal runs do not sag.
If space permits, it is generally easier to attach venting in the top vent configuration.
Because of sharp edges, always use gloves when handling the flex vent components.
Vent connections should overlap a minimum of 1" for proper sealing.
Always follow the general venting requirements for vent terminal location, vent lengths, and clearance to combustible materials.
Figure 55
Figure 57
The DVVK-5F FLEX VENT KIT includes the following components:
Figure 58
Figure 56
DVVK-5F FLEX VENT INSTRUCTIONS
•   (1) Horizontal Termination Cap
•   (1) 4-foot section of Flex vent with spacers (5" flue/8" 
outer pipe) with flue adapter collar
•  (1) Wall Firestop/Thimble Assembly
•  Hardware pack that includes band clamps and screws
SPACER
SPRINGS
FLEX FLUE PIPE
FLEX OUTER VENT