Monessen Hearth CDVR33N/PV7 User Manual

Page of 68
CDVSC7 & CDV7 Series Gas Fireplace
69D3011
11
CleaRanCeS  
CleaRanCeS To CoMBuSTIBleS 
w
a
R
n
In
G
Follow  these  instructions  carefully  to 
ensure  safe  installation.  Failure  to  follow 
instructions  exactly  can  create  a  fire 
hazard.
The  appliance  cannot  be  installed  on  a 
carpet,  tile  or  other  combustible  material 
other  than  wood  flooring.  If  installed  on 
carpet  or  vinyl  flooring,  the  appliance 
shall  be  installed  on  a  metal,  wood  or 
noncombustible  material  panel  extending 
full width and depth of the appliance.
72" 
Minimum
6”
Minimum
fP2032
wall clearances
Figure 5 - 
Ceiling and Side Wall Clearances
FP03
Ceiling
Side 
Wall
FP2285b
mantel clearances
W
X
Y
Z
A
B
C
D
Finish Wall
Header
Stud
Standoff
Top of Heat 
Exhaust Vent
FP85b
CDV33/42/47
Side View
ManTel CleaRanCeS 
noTe:  The  combustible  area  above  the  facing  must 
not  protrude  more  than  3/4"  from  the  facing.  If  it  does, 
it  is  considered  a  mantel  and  must  meet  the  mantel 
requirements listed in this manual.
 
w
a
R
n
In
G
never obstruct or modify the air inlet or 
outlet grilles (louvers). This may create 
a fire hazard.
Figure 6 -
 Mantel Clearances
Front View
6"
5"
3"
45°
1"
256O”
1
56O
3
56O
4
56O
FP2286
Mantel leg clear
Side of Fireplace 
Opening
Stud
Wall
FP86
Combustible 
Material Area
noTe: CDVR33SC7 has no standoffs.
FP2285 36
mantel clearances
12” (305 mm)
256O”
(64 mm)
13”
(330 mm)
12”
(305 mm)
Finish Wall
Header
Stud
Standoff
Top of Heat 
Exhaust Vent
FP85
CDV36
Side View
 
Ref. 
CDV33 
CDV42/47  Ref. 
CDV33 
CDV42/47
  A  14" (356 mm)  1" (305 mm)  W  1" (305 mm) 1" (305 mm)
  B  11" (79 mm)  9Z\x" (41 mm)  X  8" (03 mm)  8" (03 mm)
  C  10" (54 mm)  8Z\x" (16 mm)  Y  6" (15 mm)  6" (15 mm)
  D  8" (03 mm)  6" (15 mm) 
Z  Z\x" (64 mm)  Z\x" (64 mm)