Monessen Hearth CDVR33N/PV7 User Manual

Page of 68
CDVSC7 & CDV7 Series Gas Fireplace
69D3011
9
pRe-InSTallaTIon InFoRMaTIon
BeFoRe you STaRT
Read  this  homeowner  manual  thoroughly  and  follow  all 
instructions  carefully.  Inspect  all  contents  for  shipping 
damage and immediately inform your dealer if any damage 
is found. Do not install any unit with damaged, incomplete, 
or substitute parts. Check your packing list to verify that 
all listed parts have been received. You should have the 
following:
  Fireplace (Firebox and Burner System)  
 
  Log Set 
  Volcanic Rock
  Rock Wool 
ITeMS RequIReD FoR InSTallaTIon
Tools: 
Building Supplies:
  Phillips Screwdriver 
  Framing Materials
  Hammer 
  Wall Finishing Materials
  Saw and/or saber saw 
  Level
  Electric Drill and Bits 
  Tee Joint
  Pliers 
  Measuring Tape
  Square 
  Pipe Wrench
  Caulking Material (Noncombustible)   
  Fireplace Surround Material (Noncombustible) 
  Piping Complying with Local Codes
  Pipe Sealant Approved for use with Propane/LPG
  (Resistant to Sulfur Compounds)
FIReBox FRaMInG FoR CDVR
Firebox framing can be built before or after the appliance 
is set in place. Construct firebox framing following Figure 2 
for your specific installation requirements. Refer to Figure 
for firebox dimensions. The framing headers may rest 
on the top of the firebox standoffs. Do not bring headers 
below top of standoffs. noTe: CDVR33SC7 does not 
have standoffs.
The firebox may be installed directly on a combustible floor 
or  raised  on  a  platform  of  an  appropriate  height.  When 
the firebox is installed directly on carpeting, tile, or other 
combustible material, other than wood flooring, the firebox 
shall be installed on a metal or wood panel extending the 
full width and depth of the enclosure.
w
a
R
n
In
G
Do  not  fill  spaces  around  firebox  with 
insulation  or  other  materials.  This  could 
cause a fire.
FIReBox FRaMInG FoR CDVT
Firebox framing can be built before or after the appliance 
is set in place. Construct firebox framing following Figure 3 
for your specific installation requirements. Refer to Figure 
for firebox dimensions. The framing headers may rest 
on the top of the firebox standoffs. Do not bring headers 
below top of standoffs.
The firebox may be installed directly on a combustible floor 
or  raised  on  a  platform  of  an  appropriate  height.  When 
the firebox is installed directly on carpeting, tile, or other 
combustible material, other than wood flooring, the firebox 
shall be installed on a metal or wood panel extending the 
full width and depth of the enclosure.
no
T
e
ColD ClIMaTe InSulaTIon
If you live in a cold climate, seal all cracks around your appliance, and 
wherever cold air could enter the room, with noncombustible material. 
It is especially important to insulate the outside chase cavity between 
the studs and under the floor on which the appliance rests, if the floor 
is above ground level.