TwIST loCK pIpeS
When using  twist lock pipe it is not necessary to use seal-
ant on the joints. The only areas of the venting system that 
need to be sealed with high temperature silicone sealant 
are the sliding joints of any telescopic vent section used 
in the system.
To join twist lock pipes together, simply align the beads of 
the male end with the grooves of the female end, twisting 
the pipe until the flange on the female end contacts exter-
nal flange on the male end. It is recommended that you 
secure the joints with three (3) sheet metal screws, how-
ever, this is not mandatory with twist lock pipe. Figure 11
To make it easier to assembly the joints, we suggest put-
ting a lubricant (Vaseline or similar) on the male end of the 
twist lock pipe prior to assembly.
TWL100
Twist Lock Pipe
3/12/99   djt
Male End
Female End
Screw Holes
TWL100
Figure 11 -
Twist-lock Pipe Joints
VenTInG InSTallaTIon InFoRMaTIon
ReaR VenT InSTallaTIon only:
Install the 4” (10 mm) vent pipe to the appliance inner 
collar and secure with three (3) stainless steel sheet metal 
screws. Install the 7” (178 mm) vent pipe to the appliance 
outer collar. Secure pipe to the rear cover plate using the 
tabs  and  three  (3)  sheet  metal  screws.  If  a  45°  or  90° 
elbow is being used, attach the elbow to the appliance in 
the same manner then attach the venting to the elbow.
KT1129
cdv add rear vent
Sheet Metal 
Screws
Tabs
KT119
Figure 12 - 
Rear Vent Installation