Jøtul GF 100 DV II Nordic QT
Specifications
Input Rates
Natural Gas
17,000 BTU/hr. maximum input
   9,900 BTU/hr. minimum input
Propane
16,000 BTU/hr. maximum input
   8,700 BTU/hr. minimum input
Inlet Pressure:
          MIN
MAX
Natural Gas:   5.0 WC  (1.24 kPa)
    7.0 WC  (1.74 kPa)
Propane:       12.0 WC  (2.98 kPa)           14.6  WC  (3.63 kPa)
Manifold Pressure:
       MIN
MAX
Natural Gas:   1.2 WC  (0.29 kPa)
    3.8 WC  (0.94 kPa)
Propane:          2.9 WC  (0.72 kPa)           11.0 WC  (2.74 kPa)
Piezo Ignitor / Standing Pilot
Weight: 150 lbs.
GF 100 DV II  Miscellaneous Kit Contents
• Fuel Conversion Kit - LP................................ 155628
• Rear Air Intake Restrictor Plate, Black -22111092
                                             or Jøtul Iron - 22111085
• Side Air Intake Restrictor Plates, (2) .... 22099192
                                             or Jøtul Iron - 22099185
* Decorative Wall Shield, Black ................ 22092692
                                          or Jøtul Iron..... 22092692
GF 100 DV II  Accessories
• Blower Kit......................................................... 155631
• Antique Brick Kit ............................................ 155815
• Fuel Conversion Kit - NG .............................. 155629
• Wall Thermostat ............................................ 750003
• Remote Control .............................................. 129706
• Mobile Home Floor Bracket Kit ................. 154342
The Jøtul GF 100 DV II Nordic QT is a Direct Vent
gas heater designed as a sealed combustion, air
circulating gas appliance for residential applications.
This appliance is approved for installation using
6 5/8" X 4" vent pipe from the following manufacturers:
Simpson Dura-Vent GS
Security Vent, Ltd.
Amerivent Inc.
Selkirk Metalbestos
The Jøtul GF 100 DV II Nordic QT gas stove is
designed to burn NATURAL GAS or PROPANE only.  It
is shipped from the factory equipped to burn Natural
Gas. If use with Propane is desired, the stove must
first be converted for use with that gas. Use the LP
Fuel Conversion Kit 155628 included with this stove
See page 14 for instructions.
18 1/4”
464
mm
16 3/4 ”
425 mm
16 3/4”
425 mm
Flue Collar
Centerline
14”
356 mm
20 5/8”
524 mm
22 1/4”
565 mm
Leg To
Leg