Jotul GF 100 DV II User Manual

Page of 32
5
GF 100 DV II Nordic QT
GF 200 DV II Lillehammer
Jøtul GF 200 DV II Lillehammer
Specifications
GF 200 DV II Accessories
• Fuel Conversion Kit - NG ..................................................... 155627
• High Altitude Adjustment Kit  - NG ................................ 155808
• High Altitude  Adjustment Kit  - LP ................................. 155809
• Blower Kit ................................................................................ 155631
• Antique Brick Kit ................................................................... 155815
• Wall Thermostat .................................................................... 750003
• Remote Control ...................................................................... 129706
• Mobile Home Floor Bracket Kit .... GF 200 DV II (6”)  / 154923
............................................................. for Long Legs (8”)  / 750304
....................................................................... for Plinth Kit / 154342
• Long Leg Kits .............................................  Matte Black  / 154929
..........................................................................  Blue Black  / 154930
.....................................................................  Forest Green  / 154931
..................................................................................    Ivory  / 154932
............................................................................. Jøtul Iron / 155366
• Plinth Kits ..................................................  Matte Black /  350081
..........................................................................  Blue Black  / 350082
....................................................................................  Ivory  / 350083
..................................................................    Forest  Green  / 350084
............................................................................. Jøtul Iron / 350085
Input Rates
Natural Gas
20,000 BTU/hr. maximum input
11,400 BTU/hr. minimum input
Propane
18,000 BTU/hr. maximum input
   8,450 BTU/hr. minimum input
Inlet Pressure:
          MIN
MAX
Natural Gas:   5.0 WC  (1.24 kPa)
   7.0 WC  (1.74 kPa)
Propane:       12.0 WC  (2.98 kPa)          14.6  WC  (3.63 kPa)
Manifold Pressure:
       MIN
MAX
Natural Gas:   1.2 WC  (0.29 kPa)
    3.8 WC  (0.94 kPa)
Propane:          2.9 WC  (0.72 kPa)           11.0 WC  (2.74 kPa)
Piezo Ignitor / Standing Pilot
Weight: 180 lbs.
The Jøtul GF 200 DV II Lillihammer is a Direct
Vent gas heater designed as a sealed combustion, air
circulating gas appliance for residential applications.
This appliance is approved for installation using
6 5/8" X 4" vent pipe from the following manufacturers:
Simpson Dura-Vent GS
Security Vent, Ltd.
Amerivent Inc.
Selkirk Metalbestos
The Jøtul GF 200 DV II Lillehammer gas stove is
designed to burn NATURAL GAS or PROPANE only.
It is shipped from the factory equipped to burn
Natural Gas. If use with Propane is desired, the stove
must first be converted for use with that gas. Use
the LP Fuel Conversion Kit 155626 included with this
stove See page 14 for instructions.
GF 200 DV II Miscellaneous Kit Contents
• Fuel Conversion Kit - LP................................ 155626
• Rear Air Intake Restrictor Plate, Black -22111092
                                             or Jøtul Iron - 22111085
• Side Air Intake Restrictor Plates, (2) .... 22099192
                                             or Jøtul Iron - 22099185
* Decorative Wall Shield, Black ................ 22092692
                                          or Jøtul Iron..... 22092692
18 ”
457 mm
21 1/8”
537 mm
As shipped
with 6”
(152 mm)
Legs
Height Dimensions with Optional Legs
   Plinth Kit - subtract I” (25 mm)
    Long Legs - add 2 1/4” (57 mm)
24 3/4”
630 mm
22 3/4”
560 mm
24 3/4”
630 mm
13”
330 mm
Leg To
Leg
18  1/2”
470 mm
17 1/4”
438 mm