KitchenAid KDRU763VSS Installation Instruction

Page of 56
15
3. Pull tube to ensure it is secured. 
4. Route flexible codes approved water supply line through 
undersink cabinet and oven cabinet cutout.
5. Connect the flexible codes approved water supply line to the 
range copper tubing, using a ¼" to ¼" water supply union.
6. Turn on water supply.
7. Check all connections for leaks.
NOTE: No flushing or conditioning of the water filter is required 
prior to use.
Make Gas Connection
1. Assemble flexible connector from gas supply pipe to pressure 
regulator located in the middle rear of the range.
2. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in the following illustration). 
3. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters.
4. Use a 
¹⁵⁄₁₆" combination wrench and channel lock pliers to 
attach the flexible connector to the adapters. Check that 
connector is not kinked.   
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
A. To home water supply
B. Rear of cabinet cutout
C. Flexible codes approved water supply line from home 
water supply
D. ¼" to ¼" water supply union (supplied in water filter kit)
E. Oven copper tubing
F. Range front
Water
supply
connection
Shutoff
valve
Water supply tubing 
to cold water supply
Yellow
WATER
IN
Water supply tubing to range
Blue
WATER
OUT
Filter
Sink
B
C
D
A
E
F
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
A. Closed valve
B. Open valve
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
D
E
F
G
H
A