4
Loosen the two captive screws that attach the lamp housing to the pro-
jector.
5
Detach the lamp connector from the projector by depressing the locking 
tab on the connector and lightly pulling it free.
WARNING
:
To avoid burns, allow the projector to cool for at least 30 minutes 
before you replace the lamp.
Do not drop the lamp housing or touch the glass bulb! The glass 
may shatter and cause injury.
Be extremely careful when removing the lamp housing. In the 
unlikely event that the bulb ruptures, small glass fragments may be 
generated. The lamp housing is designed to contain these frag-
ments, but use caution when removing the lamp housing. Before 
replacing the lamp, clean the lamp compartment and dispose of 
cleaning materials. Wash hands after lamp replacement. This prod-
uct has a lamp which contains a very small amount of mercury. Dis-
pose of it as required by local, state or federal ordinances and 
regulations. For more information see www.eiae.org.
6
Carefully remove the lamp housing. Dispose of the lamp in an environ-
mentally proper manner. 
7
Install the new lamp housing and tighten the screws.
8
Re-attach the lamp connector to the projector. The locking tab should 
engage when the connector is fully plugged in.
9
Replace the lamp door.
10
Plug in the power cord and toggle the Power switch to turn the projector 
back on.
11
To reset the lamp hour timer, navigate to the Settings>Service menu 
and select Lamp Reset. See page 40 for details. Or, simultaneously press 
both Volume buttons on the keypad and hold them for 10 seconds.
lamp 
housing
lamp cable
lamp
connector
lamp
housing
captive screw
connector 
locking tab
lamp cable
captive screw
Service menu