Vinotemp 1500cd User Guide

Page of 20
                                                                                
- 14 -
c. Failed 
thermistor 
 
d. Failed 
components 
 
e. Improper 
condenser 
airflow 
f. Dirty 
condenser 
g.  Overcharge of refrigerant 
h.  Discharge or suction pressure too 
high 
c.  Check thermistor by placing it in ice 
water and measuring resistance 
d.  Check compressor windings, start 
relay and overload protector. 
e.  Check for condenser fan  
f. Clean 
condenser 
g.  Call service for removing refrigerant 
h.  Call service for OEM information 
 
8. Fan motor running but compressor not running 
 
a.  Incorrect power supply 
b.  Incorrect or loose wirings 
c. Failed 
components 
 
d.  Liquid refrigerant in the compressor 
a.  Check for proper voltage 
b.  Check all wirings and  connections 
c.  Check start relay, start capacitor, 
overload protector, compressor. 
d.  Call service for OEM information. 
9. Compressor running but fan not running 
 
a.  Fan blade stuck 
b.  Incorrect or loose wirings 
c. Failed 
motors 
a.  Check for proper clearance 
b.  Check all wirings 
c.  Call service for checking open or 
shorted windings 
10. No cooling but compressor and fan running  
 
a.  Evaporator airflow restriction 
b. Refrigerant 
leakage 
c. Refrigeration 
system restriction 
a.  Check for airflow through evaporator 
b.  Check for loss of refrigerant 
c.  Call service for checking  restrictions
11. Evaporator Icing
 
 
a.  Air flow restriction 
b. Refrigerant 
leaking 
c.  Capillary tube blockage 
 
a.  Check for fans 
b.  Check for sealed system leakage 
c.  Check for low side pressure 
 
12. House circuit tripping 
 
a.  Incorrect fuse or breaker 
b. Incorrect 
wirings 
c. Failed 
components 
 
a.  Check for proper fuse or breaker 
b.  Check for wirings and connections 
c.  Call service  
 
13. Noisy operation 
 
a.  Mounting area not firm 
b. Loose 
parts 
 
 
c.  Compressor overloaded due to high 
ambient temperatures or airflow 
restriction 
d. Malfunctioning 
components 
 
a.  Add support to improve installation 
b.  Check fan blades, bearings, cabinet 
washers, tubing contact and loose 
screws. 
c.  Check for airflow blockage 
 
 
d.  Call service for checking Internal 
loose, inadequate lubrication and 
incorrect wirings