Citel 6000 Installation Guide

Page of 43
EXTender 6000 Quick Installation Guide
 
19
 
 
Synchronous-Serial (RVP_Direct) 
This section of the manual provides the necessary information to configure the EXTender for 
connection to a synchronous-serial device. The units are programmed at the factory with 
“default” settings providing basic parameters to accommodate many network environments. 
 
Public
Branch Office
Punch Block
EXTender 6000
Punch Block
PBX
Corporate Office
 
PBXgateway
Router
DSU/CSU
DSU/CSU
Router
 
Figure 7:  
RVP_Direct Installation 
Prerequisites for Configuration 
•  The Gateway (at the corporate site) and the EXTender (at the branch office) must be installed 
properly and the network link between both devices must be operational. 
•  The network administrator must assign an IP address for both units if you plan to configure and test 
them over a LAN or WAN. 
Table 6:  
Configuration Steps 
You must...... 
To...... 
Default 
Setting 
Refer 
to... 
Set Connect 
Parameters 
Select network type  
RVP_Direct  
Setup the WAN ports 
Enable WAN ports to connect to 
network device. 
WAN 1 - 
Enabled  
Set the Sync Rate of 
the WAN port 
Match the data rate (sync rate) of the 
network device 
512,000 kbps 
Set the mode (interface 
type) of the WAN port. 
(v.35, RS-232, RS-530) 
Match the interface type of the network 
device.