Whirlpool ldr3822 User Guide

Page of 28
7
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside. 
Determine vent length
1. Select the route that will provide the straightest and most 
direct path outdoors. Plan the installation to use the fewest 
number of elbows and turns. When using elbows or making 
turns, allow as much room as possible. Bend vent gradually  
to avoid kinking. Avoid 90° turns when possible.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
The type of vent (rigid metal or flexible metal).
The number of elbows used.
Type of hood.
Recommended hood styles are shown here.
The angled hood style (shown following) is acceptable.
See the exhaust vent length chart that matches your hood type 
for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and 
increased energy usage.
3. Determine the number of elbows you will need. 
IMPORTANT: Do not use vent runs longer than specified in the 
Vent Length Chart.
Find the maximum length of metal vent on the same line as the  
number of elbows.
Vent Length Chart
InstallVentSystem
1. Before installing the vent system, be sure to remove the wire 
exhaust guard that is located at the exhaust outlet.
2. Install exhaust hood. Use caulking compound to seal exterior 
wall opening around exhaust hood.
3. Connect vent to exhaust hood. Vent must fit inside exhaust 
hood. Secure vent to exhaust hood with 4" (102 mm) clamp.
4. Run vent to dryer location. Use the straightest path possible. 
See “Determine vent length.” Avoid 90º turns. Use clamps to 
seal all joints. Do not use duct tape, screws, or other fastening 
devices that extend into the interior of the vent to secure 
the vent, because they can catch lint.
A. Louvered style
B. Box hood style
better
good
     4"
(102 mm)
      4"
(102 mm)
B
A
Number of 
90º turns 
or elbows
Type of
vent
Box or 
louvered 
hoods
Angled
hoods
0
Rigid metal
36 ft (11 m)
26 ft (7.9 m)
1
Rigid metal
26 ft (7.9 m) 
16 ft (4.9 m)
2
Rigid metal
16 ft (4.9 m)
6 ft (1.8 m)
   4"
(102 mm)
2½"
(64 mm)